Ceiling Exhaust Fans

7

®

Fig.11

Fig.10

Fig.9

Grille

Ceiling

Slot

Mounting

Spring

Fig.11

Fig.10

Fig.9

Grille

Ceiling

Slot

Mounting

Spring

CAUTION

Mount carefully so that light wiring is not pinched.

Fig.6

Circular duct 

Duct tape 

Fig. 7a

Fig. 7b

Fig.8

Attach cable clamp to Knockout Plate. 

Knockout Plate mounts to outside of 

housing and may be oriented as desired.

Connect wires with UL approved connectors.

Insert Screw from Parts Bag

Align Knockout Plate to Housing

Black
Red
Green
Wire nuts

White

Wire Nuts

inches (mm)

Caulk

Ceiling

Caulk

10-3/8 (265)

10-3/8 (265)

 

1

2

3

4

Black Wires
White Wires
Green Wires

Red Wires

IMPORTANT

After finishing the ceiling  
work, fill gap between  
flange and ceiling with  
caulk or other sealant  
to prevent air leakage.

Fig.11

Fig.10

Fig.9

Grille

Ceiling

Slot

Mounting

Spring

Fig. 9

Fig. 10

Fig. 11

Fig. 8

Fig.6

Circular duct 

Duct tape 

Fig. 7a

Fig. 7b

Fig.8

Attach cable clamp to Knockout Plate. 

Knockout Plate mounts to outside of 

housing and may be oriented as desired.

Connect wires with UL approved connectors.

Insert Screw from Parts Bag

Align Knockout Plate to Housing

Black
Red
Green
Wire nuts

White

Wire Nuts

inches (mm)

Caulk

Ceiling

Caulk

10-3/8 (265)

10-3/8 (265)

 

1

2

3

4

Black Wires
White Wires
Green Wires

Red Wires

a.  Insert the grille mounting spring on the wiring side 

into the slot. See Fig. 10

b. Insert the plug into the receptacle in the housing 

and insert the other mounting spring into the slot as 
shown and mount grille to fan body.  
See Fig. 10 and Fig. 11

10.  For model SP-AP0511WL, with light

CAUTION

• Before turning on the light, make sure the plug is 

fully engaged.

9.  Insert mounting springs into slots and mount grille to 

fan body. See Fig. 9

8.  Finish ceiling work. Ceiling hole to be aligned with 

the inside edges of the flange. See Fig. 8

Summary of Contents for SP-AP0511W

Page 1: ...ough the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protect...

Page 2: ...8 186 5 8 14 5 10 1 4 260 12 1 8 308 2 9 10 8 5 5 11 12 13 1 3 7 2 9 10 4 6 8 1 3 7 14 3 7 8 98 4 7 8 123 5 3 4 147 3 3 4 97 10 3 8 265 13 330 Model ILG8FV111 10 1 4 260 12 1 8 308 3 7 8 98 4 7 8 123...

Page 3: ...ive Light Live N Light Neutral Yellow green Red Red Signal Signal Power switch Control switch Fan body Junction box 0 5060708090 1 0 0 0 510203045 6 0 Time min 50 80110 L H Air Trimming Air Volume CFM...

Page 4: ...r a period of time delay or when humidity value is lower than set point Humidity detection value setting range 30 80 CO2 Sensor The module begins to detect environmental CO2 concentration when fan has...

Page 5: ...Adaptor Damper Tape Joists L Unit inches mm C D USB Receptacle Fig 2 a Fig 2 b Fig 1 11 3 4 22 1 2 300 579 4 Screws ST4x30 Tab Per Bryan M need image for our models is needed mper pe Unit inches mm Fi...

Page 6: ...res White Wires Green Wires Red Wires IMPORTANT Follow all local electrical and safety codes as well as the National Electrical Code NEC and the National Fire Protection Agency NFPA where applicable F...

Page 7: ...8 Insert Screw from Parts Bag Align Knockout Plate to Housing inches mm Caulk Ceiling Caulk 1 0 3 8 2 6 5 10 3 8 265 3 4 a Insert the grille mounting spring on the wiring side into the slot See Fig 1...

Page 8: ...ert the grille mounting spring on the wiring side into the slot b Insert the USB connector into the USB receptacle see page 4 for appropriate USB port configuration and insert other mounting spring in...

Page 9: ...complete the installation Fig 16 3 Screws ST4x30 Fig 16 Fig 15 Unit inches mm Fig 14 Screws ST4x30 Screws ST4x30 Screws ST4x30 Attach cable clamp to Knockout Plate Knockout Plate mounts to outside of...

Page 10: ...g 17 Fig 18 Fig 20 Fig 19 Gloves Louvers Slot Ceiling Vacuum Cleaner Mounting Spring Ceiling Gloves Fig 17 Fig 18 Fig 19 Gloves Louvers Slot Ceiling Vacuum Cleaner Mounting Spring Ceiling Fig 17 Fig 1...

Page 11: ...uct is recommended for optimal fan performance Ensure duct joints and exterior penetrations are sealed with caulk or other similar material to create an air tight path and to minimize building heat lo...

Page 12: ...er on the specific product page or in the literature section of the website at Greenheck com Resources Library Literature Phone 715 359 6171 Fax 715 355 2399 Parts 800 355 5354 E mail gfcinfo greenhec...

Reviews: