background image

Size Face

A

B

C

D

E

F

15

1.6

38

12.75 11.0 3.0 0.75

.5

20

2.2

38

12.75 14.0 4.5 0.75

.5

25

2.7

38

12.75 16.0 4.0 0.88

.5

30

3.2

38

12.75 18.5 4.0 0.88

.5

45

4.5

50

12.75 18.5 4.0 0.88

.5

50

5.2

50

12.75 21.0 4.0 1.13

.5

65

6.7

50

12.75 26.0 4.0 1.38

.5

85

8.6

62

12.75 26.0 4.0 1.38

.5

6

MSCF

Hot Water

Dimensional Data

MSCF Coil Data

Chilled Water 

Dimensional Data

6.5

J

2

1.5 3.75

A

K

B

C

13.25

18.5

1

3

.75

3.88

4, 6 or 8 Row

Size Face

A

B

C

J

K

4

6

8

4&6

8

15

1.6

38 24.5 11.0 10 12 14

0.75 1.38

20

2.2

38 24.5 14.0 10 12 14

0.75 1.38

25

2.7

38 24.5 16.0 10 12 14

0.88 1.38

30

3.2

38 24.5 18.5 10 12 14

0.88 1.38

45

4.5

50 24.5 18.5 10 12 14

0.88 1.38

50

5.2

50 24.5 21.0 10 12 14

1.38 1.63

65

6.7

50 24.5 26.0 10 12 14

1.38 1.63

85

8.6

62 24.5 26.0 10 12 14

1.38 1.63

All dimensions are in inches.

Direct Expansion (DX) 

13.25

18.5

1

A

6.5

L

N

P

3.75

3.88

M

B

C

4, 6 or 8 Row

Dimensional Data

3

2

1.5

All dimensions are in inches.

1 & 2 Row Coils

NOTE: 4 row hot water dimensions are the same as 4 row chilled water coil dat

a

 (see

below). Fluid enters the coil from the bottom connection (In) and exits from the top (Out).

In

Out

Out

In

NOTE: With airflow from left to right the fluid enters the coil from
the bottom connection (In) and exits from the top (Out). The other
two coil connections should be capped off (Cap).

Cap

Cap

Airflow

NOTE: With airflow from left to right the fluid enters the coil from
the center connection (In) and exits from the bottom (Out). The
other connections should be capped off (Cap).

Out

In

Cap

B

6

D

F

3

E

A

C

All dimensions are in inches.

Unit Face

A

B

C

L

M

N

P

Size

Area

4

6

8

All

All

4 & 6

8

15

1.6

38

24.5 11.0

8.75 10.75 12.75

5.25

0.63

0.63

1.38

20

2.2

38

24.5 14.0

8.75 10.75 12.75

7.00

0.63

0.63

1.38

25

2.7

38

24.5 16.0

8.75 10.75 12.75

8.00

0.88

1.38

1.38

30

3.2

38

24.5 18.5

8.75 10.75 12.75

9.00

0.88

1.38

1.38

45

4.5

50

24.5 18.5

8.75 10.75 12.75

9.00

0.88

1.38

1.38

50

5.2

50

24.5 21.0

8.75 10.75 12.75 10.25

0.88

1.38

1.63

65

6.7

50

24.5 26.0

8.75 10.75 12.75 13.00

1.13

1.38

1.63

85

8.6

62

24.5 26.0

8.75 10.75 12.75 13.00

1.13

1.38

1.63

1, 2, or 4 Row

Orifice Code 18/19

Airflow

Coil connection made
inside housing, 2 inch
hole is provided.

Summary of Contents for MSCF

Page 1: ...items are stored inside the unit during shipping Care must be taken during installation to prevent damage to units MODEL MSCF Modular Small Cabinet Fan Installation Operation and Maintenance Manual W...

Page 2: ...ows panels removed 9 1 1 4 in knockout for recommended electrical wiring penetration or disconnect switch 8 8 8 8 8 7 9 Table of Contents Unit Layout Table of Parts Lifting Hanging Instructions Modula...

Page 3: ...to avoid damage see figure 1 Figure 1 3 Frame Rails By others Spreader bar Lifting lugs The MSCF should be hung by the factory supplied lifting lugs or field supplied frame rails as shown respectivel...

Page 4: ...26 38 2 5 3 5 43 45 6 75 26 18 5 6 75 6 75 26 6 6 75 26 50 2 5 3 5 55 50 6 75 26 18 5 6 75 6 75 26 6 6 75 32 50 2 5 3 5 55 65 6 75 32 18 5 6 75 6 75 28 6 6 75 36 50 2 5 3 5 55 85 6 75 32 18 5 6 75 6...

Page 5: ...nit A B C D E F Size w o Filter w Filter 12 in 24 in Vertical Sloped Hot Water CW DX Fan Motor Total 15 80 107 31 57 34 61 61 145 94 50 144 20 95 126 36 68 41 72 72 171 111 50 161 25 105 140 40 75 45...

Page 6: ...same as 4 row chilled water coil data see below Fluid enters the coil from the bottom connection In and exits from the top Out In Out Out In NOTE With airflow from left to right the fluid enters the...

Page 7: ...nnection between the scroll and the discharge of the fan If noise is an issue we recommend using heavy canvas connections on the inlet of the fan Refer to the Troubleshooting section of this manual if...

Page 8: ...g good duct practices Blower speed too low Check for correct drives and RPMs with catalog data Mixing box dampers closed Open and adjust Dirty or clogged filters Clean or replace Leaks in ductwork Rep...

Page 9: ...n of water coils with low entering air conditions CONTINUOUS WATER CIRCULATION THROUGH THE COIL AT ALL TIMES IS HIGHLY RECOMMENDED 5 Pipe sizes for the system must be selected on the basis of the head...

Page 10: ...ilters are installed check by holding up to a light source If light cannot pass through the filter it should be replaced Replacement filters should be of the same manufacturer and size When reinstalli...

Page 11: ...build up from plugging the drain and causing the drain pan to overflow Inspect twice a year to avoid the possibility of overflow Also drain pans should be kept clean to prevent the spread of disease C...

Page 12: ...Up Documentation Actual Voltage Hertz Phase Actual Amperage Blower Rotation Correct Air Volume Design cfm Actual cfm Drive Level of fan L or H Fan RPM Range min max 462888 MSCF IOM APRIL 2003 Warrant...

Reviews: