GreenFlux Dual Socket Smart Charging Controller
page - 20 -
©GreenFlux Assets B.V.
–
All rights reserved.
Installation Manual; version 4.6; 2019-11-05
Doc.nr. GFX.2017.14201807
5
LOCAL MANAGEMENT
5.1
GENERAL
The controller supports a locally hosted website that can be used for configuration,
testing and analyzing purposes. Using e.g. a laptop, access can be gained by
connecting the laptop to the Ethernet (LAN) port of the controller. An internet
browser is used to start the local management website of the controller. The
connected service device will have to be configured for setting up a connection
with the charging stations ethernet LAN connection. In short:
•
IP address needs to set to
10.1.0.111
(fixed IP).
•
IMCP (IP4);
“ping”
support must be enabled (Firewall setting).
The Local Management local website is best viewed using Firefox® or Google
Chrome® and is accessible on
URL: 10.1.0.110
when connected.
5.2
SERVICE DEVICE (LAPTOP) SET UP
5.2.1
IP/SUBNET MASK SETTINGS ON SERVICE DEVICE (WINDOWS)
The service device (mostly a laptop) needs to be set up to make it ready for
connecting with the local management website of the controller. Therefor some
adjustments must be
made to the laptop’s configuration. The IP address and
firewall need to be changed for gaining access to the website of the controller. The
laptop needs a specific configuration setup to enable connecting to the charging
station controller:
•
IP address set to
10.1.0.111
(fixed IP).
•
IMCP (IP4);
“ping”
support must be enabled for all domains (Firewall
setting).
Follow the procedure below to set up the service device (Laptop) for use with local
management for a
Windows 10®
operating system. Using other types of Operating
systems (e.g. Linux® / MAC OS®) will have their own way of setting up the above
given connection requirements. This manual will not elaborate on this.
1.
Click “Start”, select “Settings” and open the “Network & Internet”
settings.
2.
In the left pane, select the topic
“Ethernet”
.
Summary of Contents for T2235-02