STRETCH
Stretch Spanks send a sequence of pulses that are the same width to Trig Out. Each pulse is
preceded by a delay which is set by the user.
The voltage level at CV Out is set by the user. Level 1 sets the voltage during the pulse and
Level 2 sets the voltage during the delay. These voltages can be scaled by using the CV Scale
control.
Parameter
Min
Max
Default
Pulse Length
10
9999
10
Delay
10
9999
100
Num Pulses
2
99
1
Level 1
0
1023
1023
Level 2
0
1023
512
The figure below illustrates a Stretch Spank with the default settings. The yellow trace is Trig
Out and the purple trace is CV Out.
Figure 4 - Default Stretch Spank
Notes: CV Output levels can be calculated using this formula:
n = 102.3*V +512
rounded
down to the nearest integer. Where n is the value to enter in Level 1 or 2 and V is the desired
output voltage. V ranges from -5V to +5V.