IP66 Rated Weatherproof
RCD Fused Spur Unit
- PSPRCD1G
PowerBreaker Protekt products are suitable for use outdoors in severe conditions of
rain and water spray as well as dust contamination to IP66 as defined by BS EN
60529. All products are for use with a 230V 50Hz supply.
INSTALLATION GUIDE - IMPORTANT
This product should be installed by a competent person and in accordance with
the current IET Wiring Regulations. If in doubt, consult a qualified electrician
Important -
• Always disconnect the mains supply via the switch in the main fuse board or
consumer unit before
commencing any electrical work.
• Ensure that all terminal screws are fully tightened and that earth wires are
sleeved and that no bare wires are showing.
• Cable glands must be used which maintain the IP rating. The warranty is
invalid if IP rating is not maintained.
Installation & Wiring Instructions
2. Any bare earth conductors must be sleeved with green/yellow sleeving.
IMPORTANT – FOR YOUR PROTECTION.
Electricity can be dangerous and the use of an RCD should not be regarded as a
substitute for basic electrical safety precautions. Always switch off from supply when
working on equipment. This device will protect against live and neutral leakage faults to
earth, it will not protect against electric shock due to contact with both conductors,
short circuits between live and neutral, or a fault in the wiring supplying this device.
Should your PowerBreaker Safety RCD Fused Spur Unit repeatedly trip with an appliance
connected or fail to trip when tested, in accordance with the instructions, return to
place of purchase.
Passive -
Mechanically latched - Does not need resetting after power failure.
Black
or Blue
Black
or Blue
Red or
Brown
Red or
Brown
Supply
Load
Load
Supply
1. Ensure that mounting surface is flat and free from loose particles and dirt.
2. Lift the lid then remove the upper portion from the back box by removing the
4 screws on installation. Please note that it is important to use a screwdriver of
a size that allows you to properly tighten these screws on installation.
3. If necessary take the back box and drill a small hole through the drainage point
that will be at the lowest point when mounted. This is necessary to ensure that
any residual moisture or condensation has an escape route at the back of the
box.
4. Use a suitable drill/wall plug for the surface on which you are mounting your
weatherproof enclosure and use No.8 countersunk screws (not supplied) to
secure the back box through the 4 corner holes.
5. Remove a suitable cable entry cover by pushing through from the inside of the
back box. If circumstances permit the best entry point for the supply cable is
the bottom one.
6. If cable entry is via 20mm conduit use the conduit gland to secure the conduit
to the back box. If entry of cable is to be direct use a suitable IP rated cable
gland.
7. Use only mains cable of sufficient rating for your application.
8. Screw down the upper portion to the back box ensuring the collar seal is in
position between the mating surface.
9. Mount the accessory onto the box, ensure the screws are securely tightened.
1. Install RCD spur and connect wires as
shown in the diagram below.
Enclosure
Installation Instructions