GreenBrook Powerbreaker J62-T Installation & Operating Instructions Download Page 1

INSTALLATION/OPERATING

INSTRUCTIONS FOR 16 AMP

230V IN-LINE PORTABLE RCD

MODEL NUMBER: J62-T

PowerBreaker J62 is a two pole in-line
portable RCD, designed for use in
commercial and industrial environments
where rough handling is expected.
The water resistant casing of the unit is
rated at IP 65 (BS 5420, IEC 144).

This product should be wired with
1.5mm

2

3 core flexible cable (BS6500).

Connect cable to the input and output
terminals, ensuring that the following is
observed.

• Live/Brown to Brown wire terminal
• Neutral/Blue to Blue wire terminal
• Earth Green/Yellow to Green/Yellow

Terminal

Ensure that there are no loose strands of
wire. To ensure the IP rating, terminals
and cover should be sealed with the
supplied sealant.

When fitting plugs, sockets or
connectors follow the accessory
manufacturer’s instructions ensuring
that the live, neutral and earth (if
any) cores are connected correctly
and the outer covering of the cable
is firmly secured.

The plug on the appliance should
be fused in accordance with the
appliance manufacturer’s
instructions.

To maintain the IP 65 weather proof
rating of the device, plugs, sockets
and connectors of an equivalent
rating must be used.

Please carry out the simple test
procedure prior to each use.

Insert plug into power socket outlet.

Press and release reset button -
the red indicator should appear in
the window.

Press the test button - the red
indicator should disappear.
This means the RCD has tripped
successfully, cutting off the power
from the RCD.

Now press and release the reset
button again, the unit is ready for
use.

WIRING

IMPORTANT

INSTRUCTIONS

Reviews: