9
W PL Lamps supplied
+
Supplied with both plain & louvered front plates
+
Fits standard house brick cavity
These instructions are for bricklight models:
LVBLB-A
and
LVBLW-A
.
WARNING: Electricity is dangerous. Installation
of this fitting must be carried out by a competent
person. If in any doubt, please consult a qualified
electrician.
INSTALLATION
This is common on both models.
Firstly, please check whether the light fixture
has been damaged during transport. When
starting installation, disconnect the power
first from the mains supply and then carry out
the following steps:-
1
. Bring a cable from the mains to the
position where you wish to install the
fitting. Make sure the cable you use is
suitable for the application.
2
. Remove the front cover, the glass and gear
tray from the fitting.
3
. Using the fitting as a template, mark, drill
and plug the mounting holes in the cavity.
With a sharp blade cut a cross in the
rubber grommet sufficient to allow
insertion of the mains cable.
4
. Insert the cables through the rubber
grommet and mount the fitting in the
cavity screwing it into position.
5
. Smother the heads of the screws and the
point of entry of the cable with silicon so
as to ensure water tightness. If you do not
do this, water will damage the fitting.
6
. Ensure that the gasket is well laid out and
screw glass and frame into position.
INSTALLATION INSTRUCTIONS FOR
IP
44 9
W PL BRICKLIGHTS