GPM - 312-A
COUNTER
INSTRUCTION MANUAL
100 Taskant street, B.R. Puram, Peelamedu,
Coimbatore - 641004.Phone no : 0422 4218101
GREEN MICROELECTRONICS INDIA PVT. LTD.
Manufacturer
Thank you very much for purchasing this GREEN product GPM - 312-A.
Please read the instruction manual carefully for the full usage of this product
The counter has passed various quality tests before despatch. Please check however,
at the time of arrival, its model code and its appearance and ensure that all the contents
are provided and there are no faults, damage etc, to the counter. Please also ensure that
the model code ,which is labeled on the counter, is identical to the one you ordered.
Note :
1. Our company shall not be liable for any damages, as described below, caused to both
any users and third parties
a) Damages caused by the result of operation of the product.
b) Damages caused by any defects in the product which are unpredictable for us.
2. The content in this manual are subject to change without any notice. If you have any
suggestion on the matter, Please do not hesitate to contact us.
GREEN
COMPONENTS FOR AUTOMATION
Introduction
Precaution for safe use
(1) Use and store the Counter within the specified ambient temperature and humidity
ranges.
(2) Do not use the product in location subject to vibrations or shocks. Using the product
in such location over a long period may result in damage due to stress.
(3) Do not use the product in locations subject to dust, corrosive gases, or direct sunlight
(4) Separate the input signal devices, input signal cables and the product from the source
of noise or high - tension cables producing noise.
- mail : greenmicroelectronics@airtel
.in
e
- www.greenelectronics.in
(5) The supplied power voltage and load must be within the rated and specified ranges.
(6) Do not use where the water or oil splatter on the counter
(7) Install a switch or circuit breaker that allows the operator to immediately turn off the
power
.
Six digits, 0.4 Inch seven segment LED
3 Keys & Displays
Two relay, 1 c/o
10 A @ 230 VAC
(Resistive load)
/ 30 VDC
5 VA
Manual, Remote
999 999 Counts
Up
SPECIFICATIONS
Front panel
Rear panel - Connection diagram
External dimensions
Panel cutout dimensions
All dimensions are in mm
75
10
90
45
24V AC, 50HZ
170 grams
96 x 48 x 75
Ambient humidity 35 to 85 % RH
10 million operation
100.000 operation
-10 to 55 c
-25 to 65 c
+ / -10% from the rated voltage
In the pack counter, side clamp and instruction manual
Wiring diagram
COUNTER
COUNTER
PNP Proximity unit
30 Hz
Memory Retension
Input Pulse and Relay
Three (Main Count, Batch Count, Time)
1
9
2
3
4
10
5
11
12
13
6
7
8
14
15
24 VDC
MAIN RLY
NO C NC
SENSOR
RESET
O / P
16
PNP
PROXIMITY
LED
85 - 265 V AC, 50HZ
SUPPLY
E P N
BC RLY
NO
C
NC
TM
Display
User programming
Output
Relay contact rating
Power consumption
Reset
Range
Count direction
Dimensions
48
96
Supply voltage
Weight
Dimension
( L x W x D)
Mechanical life of relay
Electrical life of relay
Ambient temperature
Storage temperature
Operating voltage range
GPM - 312A
GREEN
SET
INPUT PULSE
RELAY
GPM - 312A
GREEN
SET
INPUT PULSE
RELAY
Input
Pulse frequency
Special feature
Indications
Set points