2.2 Technical specifications
G6200 Water Monitoring System
Function
Monitoring EGCS discharge water in accordance with IMO
resolution MEPC.259(68) & MEPC.340(77)
Power supply
400-440VAC 50-60 Hz 3 phased
Display
7" TFT LCD color display
External communication
■
Standard: Modbus TCP/IP
■
Optional: Modbus RTU (RS-485) via converter
To be specified upon order
Sample connections
Flange Standard DIN20/JIS3/4" 10K PN10
Sample pressure
Inlet:
With pressure
reduction valve
Max 10 bar (g)
Without pressure
reduction valve
Max 2.5 bar (g)
Outlet:
Max 1.8 bar (g)
Sample temperature
0–50 °C
Sample purity
Particle size of max. 2 mm
Sample condition
The system is designed for maritime SO2 scrubber wash
water containing seawater, polluted seawater, freshwater
with NaOH, residue particles from HFO combustion, and
salts (Na2SO4 etc.).
Chemical capability and material lifetime depend on a
combination of local factors such as temperature, acidity,
oxygen, and oil among others. Therefore, always consult a
chemical compatibility database with reference to each of
the materials.
Wetted materials
(In weighted order)
PVC – PP / PPGF – PC – PET – POM – PVDF – PPS – PE
– PTFE – NBR – EPDM – FKM – PA6T/6I – 316L – AI2O3
– ETFE – Quartz glass – Glass – Epoxy preform (cured) –
polyamide 6.
Max ambient temperature
Class A 45 °C (Tested to 55 °C)
Humidity
Class B
Vibration
Class A
Emc
Class A
Enclosure & material
Class B (IP65) AISI 1008 Painted
Dimensions
600 x 1200 x 300 mm
Weight
85 kg