background image

 

                            

 

 

 

Quad 4-wire  

Quick Start Guide 

              

 

 

 

 

 

 

 

 

Summary of Contents for Quad 4-wire

Page 1: ...Quad 4 wire Quick Start Guide...

Page 2: ...al audio systems And connect up to 4 General purpose Audio line in outs This is ideal for purposes like program audio and announcements or complete user based engines with 32 channels and program audi...

Page 3: ...low To Set up a 4 Wire port first select the mode to use Select a port and scroll down to Set User Mode 4 wire Port x Set User Mode Line in out Set up this port as General Purpose Input and Output thi...

Page 4: ...x Gain becomes gain MaxGain Set the maximum gain of the input signal range is from 12 to 28 dB Threshold Set the gate function for this input The threshold is the level required for the input signal t...

Page 5: ...this channel Momentary talk is enabled as long as a corresponding trigger is active Latch talk is toggled between enabled or disabled when a trigger becomes active Latch Momentary A combination of la...

Page 6: ...s active range is from 0 dB to 24 dB and MUTE option Audio In Out Output Set the output level of the Audio Output Range is MUTE 42 to 6 dB LoopBack Set the ratio of audio feed back from the input back...

Page 7: ...Chn Send a GO signal to one specific channel Normally Set up the NOT active state of this input Out x Set up one of the two outputs Func Set up the function that will trigger this Output Active An act...

Page 8: ...pinout Pin 1 5v Capable off sourcing 200mA Pin 2 Input 1 Switch to ground to activate input 1 Pin 3 Input 2 Switch to ground to activate input 1 Pin 4 Output 1 High side of open collector capable of 5...

Page 9: ...Normal the port does not reply to a incoming call Auto answer the port automatically replies with a Hold to a call Ignore the port ignores incoming calls Set up the connection type of a 4 wire port C...

Page 10: ...the Internal Green GO network Dynamic Select the connection mode ON Use a dynamic IP If an DHCP server is on the network this will supply an IP address to the device If there is no DHCP server the de...

Page 11: ...current config of the Quad 4 wire SN xxx Serial number of the Quad 4 wire 4 wire 4a61 Firmware information 4 wire 4a61 Firmware version Nov 16 2018 Date of firmware build 09 32 09 Time of firmware bu...

Page 12: ...instructions Do not insert any objects through the ventilation slots of the unit as these could come in contact with live parts or could cause short circuits This could cause electric shock and or fir...

Page 13: ...uad 4 wire Which refer to this declaration are manufactured in the Netherlands and complies with the following product specifications and harmonized standards Safety LVD Low Voltage Directive 2014 35...

Reviews: