Installation / Operating
Instructions for
7
Day
Electronic Immersion Heater Timer
- T
106
A-C
WIRING THE TIMER
Drill two 6mm holes 97mm vertically apart in the
wall. Insert plastic anchor (supplied) into holes and
fit one No.6 screw to top hole leaving a gap under
the screw head of approximately 4.75mm. Place
the keyhole slot over the screw and slide the timer
down; if the timer is loose remove it, tighten the
screw and refit the timer. Continue to do this until
the timer fits securely against the wall. Remove
terminal cover “D” by undoing screw “C”. lnsert
the second No.6 screw into slot “B ”and tighten.
Your timer is now ready for wiring.
FIXING THE TIMER
TO THE WALL
Ensure the correct cable cut-outs have been
removed in terminal cover “D” and refit terminal
cover “D ” and tighten screw “C”.
N.B. Check all terminal screws are tight.
Your GreenBrook timer should be wired from a fused spur.
We recommend a PowerBreaker H92 RCD model.
Switch off the mains and isolate
the supply by removing the appropriate fuse
before starting the installation.
Prepare cables for connection to the timer, (see
Diagram A).
The maximum size cable that can be used with this
timer is 2.5mm. If flat twin and earth cable is used
the bare earth cable must be fitted with
green/yellow sleeving before fitting the earth
terminal.
Fit the bare wire ends into the correct terminals
(see diagram A). You must ensure that there are
no loose strands left out of the terminals.
Firmly tighten all the screws.
Using the cable clamps and screws provided and
ensuring the cable clamp is fitted the correct way
round, tightly secure the cable into position.
Red or Brown
Black or Blue
Green or yellow
Diagram A
From mains
L = Red or Brown
N = Black or Blue
= Green or Yellow
To appliance
1. Press the R button to reset the timer to its
default settings, activate using a pencil or
simular pointed instrument. (pressing R will
delete all stored programmes)
2. Press Y to enter function setup. (Note: if
another button is not pressed within 10 seconds
the display will revert to the normal screen).
3. Use the + or - button to scroll to the clock icon
(flashing) and press Y to enter the current time
setting mode (hours flashing).
4. If you keep the + or - buttons pressed for more
than 3 seconds, the display will enter fast scroll
mode.
5. Use the + or - button to adjust the hours and
press Y to confirm, minutes will flash.
6. Use the + or - button to adjust the minutes and
press Y to confirm, day will flash.
7. Use the + or - button to adjust the day and
press N to exit.
CURRENT TIME AND
DAY SETTING
PROGRAMMING THE
SWITCHING TIMES
1. There are 24 ON/OFF programmes available.
2. Press the Y button twice to enter the
programming setting mode.(Note: if another
button is not pressed within 10 seconds the
display will revert to the normal screen).
Please read the instructions fully before attempting
installation.
IMPORTANT
This unit should be installed to current
IET wiring regulations if in doubt
consult a qualified electrician.
• Timer must not be mounted on a flammable
surface.
• Ensure that the timer does not come into
contact with any combustible materials such
as towels or bedding.
• Ensure at least a 300mm air space is allowed
around the timer.
B
C
D
T106A-C Ins Feb 18.qxp_Layout 1 23/02/2018 14:06 Page 1