Green Brook M22W Installation Instructions Download Page 1

IMPORTANT 

This product should be installed by a

competent person and in 

accordance with the current IET

Wiring Regulations. If in doubt, 

consult a qualified electrician.

  

Electricity is dangerous and an RCD

must not be used as a substitute for

normal precautionary measures.

Always disconnect from mains supply

before any inspection or repair to

equipment is carried out. Do not

allow children to tamper with 

electrical devices.
This device will protect against live

and neutral leakage faults to earth, it

will not protect against electric shock

due to contact with both 

conductors, short circuits between

live and neutral, or a fault in the

wiring supply to this device.
This a Type AC RCD.

Type AC RCD should not be fitted

upstream of a Type A RCD as the

load characteristics of a Type A RCD

could then  impair operation of the

Type AC RCD.

TO FIT THIS SAFETYSURE RCD SOCKET –

Switch off the power supply at the

mains in order to isolate the existing

socket. Remove the old socket, then

for the Unswitched models 

M22W

and 

M22M

simply connect using the

wiring diagram below.

Or for switched sockets 

M22SW

and

M22SM

follow the diagram below.

If earth conductors are bare, they

must be sleeved with appropriate

green/yellow sleeving.

If you are in any doubt about 

connecting this product consult a 

qualified electrician.

Blue(N)

Brown(L)

Green/Yellow(E)

Installation Instructions for 

SafetySure Twin RCD Socket

M22W, M22M & Switched versions

M22SW, M22SM

Blue(N)

Brown(L)

Green/Yellow(E)

E

L

N

E