background image

Multi Variable Air Conditioners Duct Type Indoor Unit 

1 Safety Precautions 

 

WARNING

 

(1) 

This product can’t be installed at corrosive, inflammable or explosive environment or the place with special 
requirements, such as kitchen. Otherwise, it will affect the normal operation or shorten the service life of 
the unit, or even cause fire hazard or serious injury. As for above special places, please adopt special air 
conditioner with anti-corrosive or anti-explosion function. 

(2)  Follow this instruction to complete the installation work. Please carefully read this manual before unit 

startup and service. 

(3)  Wire size of power cord should be large enough. The damaged power cord and connection wire should be 

replaced by exclusive cable. 

(4)  After connecting the power cord, please fix the electric box cover properly in order to avoid accident. 

(5)  Never fail to comply with the nitrogen charge requirements. Charge nitrogen when welding pipes. 

(6)  Never short-circuit or cancel the pressure switch to prevent unit damage.   

(7)  Please firstly connect the wired controller before energization, otherwise wired controller can not be used. 

(8)  Before using the unit, please check if the piping and wiring are correct to avoid water leakage, refrigerant 

leakage, electric shock, or fire etc. 

(9)  Do not insert fingers or objects into air outlet/inlet grille. 

(10) Open the door and window and keep good ventilation in the room to avoid oxygen deficit when the gas/oil 

supplied heating equipment is used. 

(11) Never start up or shut off the air conditioner by means of directly plug or unplug the power cord. 

(12) Turn off the unit after it runs at least five minutes; otherwise it will influence oil return of the compressor. 

(13) Do not allow children operate this unit. 

(14) Do not operate this unit with wet hands. 

(15) Turn off the unit or cut off the power supply before cleaning the unit, otherwise electric shock or injury may 

happen. 

(16) Never spray or flush water towards unit, otherwise malfunction or electric shock may happen. 

(17) Do not expose the unit to the moist or corrosive circumstances. 

(18) Under cooling mode, please don't set the room temperature too low and keep the temperature difference 

between indoor and outdoor unit within 5

  (41

). 

(19) User is not allowed to repair the unit. Fault service may cause electric shock or fire accidents. Please 

contact Gree appointed service center for help.   

(20) Before installation, please check if the power supply is in accordance with the requirements specified on 

the nameplate. And also take care of the power safety. 

Summary of Contents for ULTRA heating GMVND07PLS/A-T

Page 1: ...ginal Instructions Commercial Air Conditioners Multi Variable Air Conditioners Ducted Type Indoor Unit Models GMV ND07PLS A T U GMV ND09PLS A T U GMV ND12PLS A T U GMV ND14PLS A T U GMV ND18PLS A T U...

Page 2: ...eration of this unit please read and follow the instructions carefully 4 During operation total capacity of indoor units should not exceed the total capacity of outdoor units Otherwise poor effect of...

Page 3: ...nd knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not pl...

Page 4: ...nage System Testing 9 4 4 Installation of Air Duct 12 4 5 Installation of Wired Controller 15 5 Wiring Work 15 5 1 Connection of Wire and Patch Board Terminal 15 5 2 Power Cord Connection 16 5 3 Conne...

Page 5: ...piping and wiring are correct to avoid water leakage refrigerant leakage electric shock or fire etc 9 Do not insert fingers or objects into air outlet inlet grille 10 Open the door and window and kee...

Page 6: ...onous gas will emerge if the refrigerant gas meets fire 26 Volatile liquid such as diluent or gas will damage the unit appearance Only use soft cloth with a little neutral detergent to clean the outer...

Page 7: ...together with the hanger bolt for installing the unit 5 M10 Nut M10X8 4 Nut 4 To be used together with the hanger bolt for installing the unit 6 M10 Washer Spring Washer M10X2 6 4 To be used together...

Page 8: ...ence and noise Even if the distance is 1m 39 3 8 in when there is strong electric wave noise may still occur Unit mm in Fig 3 2 1 1 The unit shall be installed in accordance with national standards or...

Page 9: ...Indoor Unit and Outdoor Unit Fig 3 3 2 Material Type Total Length L m ft of Communication Cable between Indoor Unit and Indoor Outdoor Unit Wire size mm2 AWG Material Standard Remarks Light Ordinary p...

Page 10: ...ies please lower the capacity appropriately according to the specifications of power cord and air switch provided by manufacturer 4 Install cut off device near the unit The minimum distance between ea...

Page 11: ...15 24 1 4 200 7 7 8 121 4 3 4 928 36 1 2 161 6 3 8 980 38 5 8 GMV ND22 PLS A T U 4 1 2 Suspend the indoor unit 1 Drill bolt holes and install bolts 1 Stick the reference cardboard on the installation...

Page 12: ...r return outlet or air outlet you can need to reinforce the ceiling to prevent vibration For detailes please consult user or builder If the strength of the ceiling is not good please install a beam br...

Page 13: ...according to the following fig and arrange insulation to the drainage pipe Improper installation may lead to water leakage and damp the furniture and other things in the room 4 You can buy normal hard...

Page 14: ...onnecting several drain pipes follow the instruction as indicated in Fig 4 3 4 Choose the drain collecting pipe that matches with unit capacity Fig 4 3 4 5 Install the trap as shown in following Fig 4...

Page 15: ...he raising pipe is vertical with the unit the raising height should be less than C Unit mm in Fig 4 3 9 Unit mm in Model A B C GMV ND07PLS A T U GMV ND09PLS A T U GMV ND12PLS A T U GMV ND14PLS A T U G...

Page 16: ...kage occur 3 It is strongly recommend to do the drain test before ceiling decoration Fig 4 3 11 4 4 Installation of Air Duct Note There should be insulating layer on air out duct air return duct and f...

Page 17: ...een 3 Canvas Duct 7 Main Supply Air Duct 4 Return Air Inlet 8 Supply Air Outlet 2 Installation of Circular Duct Fig 4 4 2 No Name No Name 1 Return Air Duct 6 Transition Pipe 2 Canvas Duct 7 Supply Air...

Page 18: ...bottom as shown in Fig 4 4 5 Fig 4 4 5 2 If the bottom return air is desired just change the place of the rectangular flange and the return air cover plate 3 Connect one end of the return air duct to...

Page 19: ...ic shock 2 Please carefully read the wiring diagram before carry out the wiring work incorrect wiring could cause malfunction or even damage the unit 3 The unit should be powered by independent circui...

Page 20: ...e ring tongue terminal and tighten by crimping tool 4 Use the screwdriver for tightening the terminal Unit mm in Fig 5 1 1 Fig 5 1 2 5 2 Power Cord Connection NOTICE Every unit should be equipped with...

Page 21: ...n in fig 5 3 2 terminal resistor is provided with each ODU 5 4 Connect Communication Wire of Wired Controller 1 Open electric box cover of indoor unit 2 Let the communication wire go through the rubbe...

Page 22: ...t must be set as master one and slave one 4 One wired controller can control 16 indoor unitS in maximum at the same time as shown in fig 5 5 1 1 The type of indoor units must be the same if they are c...

Page 23: ...Multi Variable Air Conditioners Ducted Type Indoor Unit 19 Fig 5 5 1...

Page 24: ...e a vacuum cleaner to remove dust If the filters are dirty wash them with warm water and mild detergent and dry the filters in the shade 2 If the unit used in the environment with much dust please cle...

Page 25: ...epair may cause electric shock or fire so please contact an authorized service center for professional service The following checks prior to contact may save your time and money Phenomenon Troubleshoo...

Page 26: ......

Reviews: