39
Service Manual
Cooling unitt
Cooling and heating unit
LIVV09HP115V1A
LIVV12HP115V1A
Connection pipe specification:
Liquid pipe:1/4"
Gas pipe:3/8" / 1/2"
Indoor unit
Outdoor unit
COOLING
HEATING
4-Way valve
Discharge
Suction
Heat
exchanger
(evaporator)
Heat
exchanger
(condenser)
Valve
Valve
Liquid pipe
side
Gas pipe
side
Strainer
Electron
expansion
valve
Strainer
Accumlator
Compressor