Gree GDN20AX-K4EBA1A Owner'S Manual Download Page 1

Dehumidifier

         

If you have lost the Owner’s Manual, please contact the local agent or visit 

www.gree.com or sent email to [email protected] for electronic version.

Thank you for choosing our product.

For proper operation, please read and keep this manual carefully. 

Model: GDN20AX-K4EBA1A

GDN20AX-K4EBA1B

Summary of Contents for GDN20AX-K4EBA1A

Page 1: ...please contact the local agent or visit www gree com or sent email to global gree com cn for electronic version Thank you for choosing our product For proper operation please read and keep this manual...

Page 2: ...3 Check Before Operation 4 Operation Instructions Operation Method 5 Drainage Method Maintenance Clean and Maintenance 11 Malfunction Troubleshooting 13 Error Codes 15 Note Graphics in this manual are...

Page 3: ...ny heating appliances near the dehumidifier Do not move get the power plug with wet hands Please use grounded power cord and make sure it s well conne cted and not damaged Children and disabled people...

Page 4: ...d other outside openings of the room to improve the working effect Please keep the air inlet outlet clean and not blocked Avoid direct sunlight Note Note 20cm at least 50cm at least 20cm at least The...

Page 5: ...Parts Name Front Side Back Side 3 Control Panel Air outlet Display Window Cover plate continous drainge Air in grille Water Bucket Fixing hole of power cord Power cord...

Page 6: ...n both sides of the water bucket and pull it out following the arrow direction moved a little after long time transportation If it s not placed properly move it to the correct position by hand 3 Repla...

Page 7: ...mer Button Speed Indicator Timer Indicator Filter Cleaning Indicator Dehumidify mode indicator Bucket Full Indicator Display Window Press Timer button to set timer on or timer off The timer can be set...

Page 8: ...dehumidify mode The unit will always dehumidify only until the humidity is decreased to the inapplicable humidity of human If the quiet indicator is on the unit enter into quiet mode The unit will in...

Page 9: ...his indicates that bucket is full or removed or not placed correctly 4 Filter reset When the indicator of filter clean is on it needs to clean filter After filter is cleaned press Fan button and Humid...

Page 10: ...Do not use the hose if using water bucket to collect water When the hose is connected water will be drained out through it instead of into the bucket 1 Hold the handles on both sides of the water buc...

Page 11: ...g at first rotate the drainage adapter into the continuos drain outlet in clockwise direction Pull the drainage adapter through the continuous drain outlet and then rotate it into the drain outlet of...

Page 12: ...densate water can be drained out smoothly Please check drainage adapter and drain hose periodi cally to see whether they are connected tightly and whether they are damaged or blocked Note Please make...

Page 13: ...Do not open it forcibly or open the angle too large As shown in fig pull up the panel to remove it 2 Remove air filter As shown in fig pull the clasps of air filter outwards to remove the air filter 3...

Page 14: ...me Storage 12 Warning Otherwise the evaporator will catch dust and affect unit s performance Do not dry the air filter with fire or electric hair dryer Otherwise the air filter may be unshaped or caug...

Page 15: ...perating in a room where temperature is from 5 to 15 C it will start to defrost automati cally Compressor will stop for a brief period of time fan will operate in high fan speed normal operation emitt...

Page 16: ...en removed Empty the bucket and replace it Unit can function normally but it can not start up Humidity is set too high If you want the air drier press button to lower the for unit to dehumidify contin...

Page 17: ...ature sensor is damaged Please refer to Chec king Table for Temperature Sen sor Resistance Display board is damaged 2 Tube Temperature Sensor Malfunction F2 Temperature sensor on the evaporator is loo...

Page 18: ...y Window 4 Freon lacking protection F0 The compr essor stops the fan mo tor keeps on running Refrigerant is leaking System is blocked 5 Overload protection H3 Ambient operation condition is bad The ev...

Page 19: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66160000222...