Gree GDN20AT-K5EBA1A Original Instructions Manual Download Page 1

Change for life

Thank you for choosing our product.

Please read this Owner’s Manual carefully before operation and 

retain it for future reference.
If you have lost the Owner's Manual, please contact the local agent 

or visit www.gree.com or send an email to [email protected] for 

the electronic version.

Owner's Manual

Original Instructions

Dehumidifier

Models:GDN20AT-K5EBA1A

GDN40AU-K5EBA1A

Summary of Contents for GDN20AT-K5EBA1A

Page 1: ...efore operation and retain it for future reference If you have lost the Owner s Manual please contact the local agent or visit www gree com or send an email to global gree com cn for the electronic ve...

Page 2: ...ence and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do...

Page 3: ...components that produced by other manufacturers 6 After verification the problem or dispute is caused by the quality specification or majeure 7 The damage is caused by natural calamities bad using en...

Page 4: ...ual first Appliance filled with flammable gas R290 Appliance shall be installed operated and stored in a room with a floor area larger The appliance shall be stored in a room without continuously oper...

Page 5: ...it s well conne cted and not damaged Children and disabled people are not allowed to use the dehum idifier without supervision Keep children from playing or climbing on the dehumidifier Memory functi...

Page 6: ...al or industrial applications Close all doors windows and other outside openings of the room to improve the working effect Please keep the air inlet outlet clean and not blocked Avoid direct sunlight...

Page 7: ...Parts Name Front Side Back Side 4 Control Panel Air outlet Cover plate continous drainge Air inlet Water Bucket Fixing hole of power cord Power cord...

Page 8: ...n both sides of the water bucket and pull it out following the arrow direction moved a little after long time transportation If it s not placed properly move it to the correct position by hand 3 Repla...

Page 9: ...power indicator on the control panel will be on and 1 ON OFF Button 2 Timer Button Press Timer button to set timer on or timer off The timer can be set in 1h increment among 0 24h with each press of...

Page 10: ...unit will always dehumidify only until the humidity is decreased to the inapplicable humidity of human If the dry indicator is on the unit enters into dry mode After clothes are dried room humidity w...

Page 11: ...will be memorized After power recovery the unit will resume operate according to the memorized settings 4 Bucket full light This indicates that bucket is full or removed or not placed correctly 5 Filt...

Page 12: ...Do not use the hose if using water bucket to collect water When the hose is connected water will be drained out through it instead of into the bucket 1 Hold the handles on both sides of the water buc...

Page 13: ...g at first rotate the drainage adapter into the continuos drain outlet in clockwise direction Pull the drainage adapter through the continuous drain outlet and then rotate it into the drain outlet of...

Page 14: ...densate water can be drained out smoothly Please check drainage adapter and drain hose periodi cally to see whether they are connected tightly and whether they are damaged or blocked Note Please make...

Page 15: ...oo large As shown in fig pull up the panel to remove it 2 Remove air filter As shown in fig pull the clasps of air filter outwards to remove the air filter 2 Air Filter Warning Otherwise the evaporato...

Page 16: ...perly The side with foam plastic should be beneath the drain lid Do not remove the foam plastic on the float GDN20AT K5EBA1A 1 Take out the water bucket and then pour out the residual water 2 As shown...

Page 17: ...Use season Disconnect power Empty the water bucket Care After Use season steps below in order to maintain the unit in good condition Make sure the water inside the water bucket is poured out and then...

Page 18: ...perating in a room where temperature is from 5 to 15 C it will start to defrost automati cally Compressor will stop for a brief period of time fan will operate in high fan speed normal operation emitt...

Page 19: ...en removed Empty the bucket and replace it Unit can function normally but it can not start up Humidity is set too high If you want the air drier press button to lower the for unit to dehumidify contin...

Page 20: ...ture sensor is damaged Please refer to Chec king Table for Temperature Sen sor Resistance Display board is damaged 2 Tube Temperature Sensor Malfunction F2 Temperature sensor on the evaporator is loos...

Page 21: ...d protection H3 E5 Ambient operation condition is bad The evaporator and condenser are blocked with filth The system is abnormal 18 Overcurrent protection Relay is short circuited or broken circuited...

Page 22: ...Please refer to which one on the unit 19 C RT1 CN4 TEMP SENSOR TUBE CN1 M2 MOTOR STEPPING CN2 CN1 CN3 CN5 DISPLAY BOARD CN1 HUMIDITY SENSOR X1 X2 LIQUID LEVEL SWITCH AP1 CN3 N1 N AC L1 MAIN BOARD AP2...

Page 23: ...potentially toxic or flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants i e non sparking adequately sealed or intrinsically...

Page 24: ...all include initial safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfactor...

Page 25: ...inguished remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazing If a leakage of refrigerant is found which requires brazing all...

Page 26: ...mpletion of charging but prior to commissioning A follow up leak test shall be carried out prior to leaving the site Ensure that contamination of different refrigerants does not occur when using charg...

Page 27: ...order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shall be in good working order with a set of instructions concerning the equipment tha...

Page 28: ...600005061021 GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com...

Reviews: