Page 1: ...Owner s Manual Original Instructions Portable Commissioning Tool Pro Model CE42 24 F C ...
Page 2: ...al is a universal manual some functions are only applicable to particular product All the illustrations and information in the instruction manual are only for reference and control interface should be subject to actual operation 3 In order to make the product better we will continuously conduct improvement and innovation We have the right to make necessary revision to the product from time to time...
Page 3: ... Instructions 9 3 1 Unit Type Selection 9 3 2 Main Page Display and Buttons 9 3 3 General Buttons 10 3 4 Buttons Operation Instructions 11 4 Function Instructions 11 4 1 CAN Communication Unit Multi VRF Function Instructions 11 4 2 RS485 AC Unit U match Function Instructions 16 4 3 RS485 Water Heater Function Instructions 18 4 4 Controller Setting 20 4 5 Help Information 23 ...
Page 4: ...n may cause severe damage or death to people This sign indicates that the items must be observed Improper operation may cause damage to people or property WARNING This product can t be installed at corrosive inflammable or explosive environment or the place with special requirements such as kitchen Otherwise it will affect the normal operation or shorten the service life of the unit or even cause ...
Page 5: ...l Pro 2 2 Wiring Instructions Fig 2 1 Parts of Controller No Name Touch screen of controller Rear cover of controller Adapter board Short connection wire Long connection wire Quantity 1 1 1 1 1 Unit mm Fig 2 2 Outline Dimension ...
Page 6: ...1 Wiring Interfaces Interface symbol COM USB Meaning Interface of power supply and communication Power supply connect to PC 2 2 2 Power Supply Ways 1 Power supply way 1 Power is supplied through USB Micro interface USB symbol 2 Power supply way 2 Connection unit through 4 core communication wire Power is supplied by unit This power supply way will be adopted for site enviroment 2 2 3 CAN Comunicat...
Page 7: ...Portable Commissioning Tool Pro 4 Fig 2 3 Connected with IDU Network of CAN Comunication Unit Fig 2 4 Debugger Interface in IDU Mainboard of CAN Comunication Unit ...
Page 8: ...ommissioning Tool Pro 5 Method 2 Connect with ODU network of CAN comunication unit Fig 2 5 Connected with ODU Network of CAN Comunication Unit Fig 2 6 Debugger Interface in ODU Mainboard of CAN comunication unit ...
Page 9: ...rk connect according to Fig 2 5 during connection one end of 4 core long connection wire is connected with COM interface of this product the other end is connected with CN2 interface of ODU mainboard Fig 2 6 4 DIP of ODU address shall be set You must set this DIP in main control ODU The setting code SA8 of main control unit shall be set to 00 Otherwise it is invalid NOTE The debugging interfaces i...
Page 10: ...ructions 1 This product is applicable to the RS485 AC unit and can be connected to the unit network through the IDU 2 If the product is connected to the network through the IDU connect according to Fig 2 7 During connection one end of the 4 core long connection wire is connected with COM interface of this product and the other end is connected to the COM1 or COM2 interface of the IDU ...
Page 11: ...ect according to Fig 2 9 During connection one end of the 4 core long connection wire is connected with COM interface of this product and the other end is connected to the adapter board of the product The adapter board is connected to the Unit interface of the wired controller through the 4 core short connection wire The communication line originally connected to the Unit interface is plugged into...
Page 12: ...it Type Selection Page This product supports CAN communication unit Multi VRF RS485 AC unit U match RS485 Water Heater three types of units after the product is powered on automatically determine the connected unit type without the user to manually select 3 2 Main Page Display and Buttons Fig 3 2 Main Page ...
Page 13: ...rance of viewing IDU status parameters Project setting Entrance of project setting options ODU error indication When this icon appears it indicates ODU module has error currently ODU status Entrance of viewing ODU status parameters Unit control Entrance of unit control operation Unit debugging Entrance of unit debugging operation System status Entrance of viewing system status parameters 3 3 Gener...
Page 14: ...responding page take IDU parameter setting page as an example Press it to enter parameter setting of this item 3 Icon Text According to the meaning of Text select a certain function or enter a certain page take sound setting as an example Press it to enter sound setting page 4 Function Instructions 4 1 CAN Communication Unit Multi VRF Function Instructions 4 1 1 System Status On the home page of C...
Page 15: ...munication unit Fig 4 2 CAN Communication Unit Viewing ODU Parameters NOTE When the module has error click at the right lower corner to enter into viewing module error 4 1 3 IDU Status On the home page of CAN communication unit press to enter into viewing IDU status of CAN communication unit Fig 4 3 CAN Communication Unit Viewing IDU Parameters ...
Page 16: ...ick IDU project code button in the list to enter into viewing detailed IDU parameters 4 1 4 Unit Debugging On the home page of CAN communication unit press to enter into unit debugging of CAN communication unit Fig 4 4 CAN Communication Unit Unit Debugging NOTE During debugging you need to click to enter into the next debugging in certain steps 4 1 5 Unit Control On the home page of CAN communicat...
Page 17: ... temperature fan speed and swing can t be set 2 Mode setting Press the Mode button to set unit s operation mode Modes for indoor units of different series are not all the same If a certain mode is not available for the indoor unit the icon of the corresponding mode cannot be selected 3 Temperature setting Press the up or down buttons to adjust temperature Each time pressing the button will increas...
Page 18: ... disabled 4 1 6 Project Setting On the home page of CAN communication unit press to enter into project setting interface of CAN communication unit Fig 4 6 CAN Communication Unit Project Setting 4 1 7 Unit Program Upgrade This product has a batch program upgrade for the controller of the indoor unit outdoor unit and compressor drive of the CAN communication unit via the communication network Only c...
Page 19: ...formation WARNING Please ensure the correctness of the program file otherwise the upgrade product will not be used During the program upgrade process please keep the product powered on 4 2 RS485 AC Unit U match Function Instructions 4 2 1 ODU Status On the home page of RS485 AC unit press to enter into viewing ODU status of of RS485 AC unit ...
Page 20: ...meters 4 2 2 IDU Status On the home page of RS485 AC unit press to enter into viewing IDU status of of RS485 AC unit Fig 4 10 RS485 AC Unit Viewing IDU Parameters 4 2 3 Unit Control On the home page of RS485 AC unit press to enter into the page of RS485 AC unit unit control ...
Page 21: ...t setting interface of RS485 AC unit Fig 4 12 RS485 AC Unit Project Setting NOTE The IDU program upgrade the ODU program upgrade and the system time setting are set to the reserved function 4 3 RS485 Water Heater Function Instructions 4 3 1 ODU Status On the home page of RS485 Water Heater press to enter into viewing ODU status of of RS485 Water Heater ...
Page 22: ...eters On the home page of RS485 Water Heater press to enter into viewing Wired Controller Parameters of RS485 Water Heater Fig 4 14 RS485 Water Heater Viewing Wired Controller Parameters 4 3 3 Project Setting On the home page of RS485 Water Heater press to enter into project setting interface of RS485 Water Heater ...
Page 23: ... which are respectively on the project setting page of CAN communication unit Multi VRF RS485 AC unit U match RS485 Water Heater On the project setting page click to enter the controller setting page This controller setting is mainly for the product itself regardless of whether the communication is connected or not Fig 4 16 Controller Setting ...
Page 24: ... NOTE When the product is in sleep mode user can wake it up by touching any part of the touch screen or the touch button at the right upper button of the screen 3 Comissioning tool program upgrade On the controller settings page click the button to enter the program upgrade page Fig 4 17 Program Upgrade File List NOTE The program upgrade needs to first connect the commissioning tool to the PC via ...
Page 25: ...he product powered on 4 Resume setting Click to enter into ex factory setting resume page After confirming local setting will resume ex factory setting 5 USB This product has 4GB of built in storage space for unit operation needs data file saving program upgrade and other functions It can be switched between USB Device mode and normal mode by connecting disconnecting the PC In the USB Device mode ...
Page 26: ...ng deleted or other changes the unit may fail to start operate abnormally etc save files of communication data and program upgrade file Outside these file operations on other files are prohibited Due to space constraints please cut the communication data save file to other storage devices in time 4 5 Help Information On the home page click at the right upper corner to enter help page Fig 4 20 List...