PL5500 Planter
Preparation and Setup
Great Plains | 411-633M | 10/21/2021
13
Console Installation
Install the console using the instructions provided in
the console manual.
Once powered on, the main menu will display
preprogrammed default settings.To reduce field time
and errors, prior to field use, it may be beneficial to
program additional settings in advance.
Refer to your seed monitoring system and/or console
operator manuals for system information and
operations.
PTO (Option)
Entanglement and Crushing Hazard
Use extreme caution in the hitch area when the PTO
is operating. Check essential personnel for long
hair, scarfs, cords, frays, loose flaps, and anything
else that might become entangled.
Refer to your tractor manual for PTO operation; follow
all PTO requirements and recommendations of the
tractor manufacturer. Read, and understand, all
decals and warning labels on the equipment being
used. The PTO pump may be mounted before or
after hitching the planter to the tractor.
PTO Tractor Requirements
The PTO pump assembly requires:
a rear-facing ASABE or ASAE Type 1 PTO stub
shaft (5) with master shield (6)
1 3/8 inch (33 mm) 6-spline,
clockwise rotation (as viewed from tractor rear,
facing forward),
a live or independent PTO drive system, that can
be operated with the tractor stationary,
a fixed or available shaft speed of 540 rpm, and
an available PTO power output of 5 hp (3.7 kW),
a drawbar (7) that engages the torque arm of the
PTO pump assembly, and
a chain anchor point (8) - a stable, non-moving
component of the tractor, within reach of the
pump’s torque arm chain.
PTO Pump Clearance
If the PTO is not known to conform to Type 1
specifications, check the follow pump-specific
clearance dimensions:
a. Shaft to master shield top:
3 1/2 inches (8.9 cm) minimum
or hinged lid
b. Shaft to master shield sides:
5 inches (12.7 cm) minimum
c. Shaft to drawbar top:
9 inches (22.8 cm) minimum
15 inches (38.1 cm) maximum
It may be necessary to invert an offset drawbar,
or relocate or remove any clevis installed on the
drawbar.
d. Shaft to ground:
16 inches (40.6 cm) minimum
!
8
34618
6
7
5
a
34623
b
c
d