PL5200 Planter
Table of Contents
Index
Adjustments
Great Plains | 411-825M | 12/07/2020
42
Seed Meter Setup and Adjustments
The only seed meter adjustments are for the seed
inlet gate, a choice of disks, and meter pressure.
Seed Meter Rain Cover
The rain cover keeps side winds from pushing seed
out of the disk cells. It also keeps precipitation,
sunlight, and field debris out of the meters. It acts to
direct any dust or debris coming from the seed
downward toward the soil. A knockout brush on the
inside of the cover brushes loose seeds off the seed disk.
To remove the rain cover:
1. Unclasp the latches (1 and 2).
2. Pivot the cover forward and down at the tab (3)
and remove.
When removing a cover, inspect it for damage and
missing parts. If a cover does not have both latches it
can be lost during transport or field operations. Also,
inspect the knockout brush for wear.
To replace a latch, slide the replacement latch onto
the cover lugs from the meter side, then snap the
other end down over the lugs.
To replace the knockout brush, see “
Knockout
Brush Replacement
” on page 63.
Seed Disk Installation
Population Risk
Make sure to use the same disk in all active
rows.
1. Check the part number and description on the
seed meter disks against the seed rate chart
data.
2. Before installing, inspect the disks. Do not install
damaged or worn disks which can cause
irregular seeding. Chips and cracks can increase
brush wear.
3. Remove the meter rain cover.
4. Inspect the meter and brushes (see page 61 for
details).
5. Make sure the seed meter clamp (1) is aligned
with the disk seat (2).
6. With the seed cells side facing the meter
housing, place the new seed disk on the disk
seat.
7. Rotate the seed meter clamp (1) clockwise 45° to
clamp the disk. The clamp will seat into the seed
disk hub (2).
With a new meter or new brushes, force the disk
into the brushes to position the seed meter
clamp. The brushes will be trained during initial
rotations.
With slightly used brushes, when a disk is first
clamped, the disk hub may be flat with the disk
seat only on the gate side. The disk should seat
as it first turns. This condition will ease as the
brushes are used.
8. Rotate disks forward a few turns after disk
installation to make sure the meter brushes lean
in the correct direction. This is particularly
important for new brushes. It will improve meter
performance and reduce air consumption.
9. Set the seed inlet gate to the setting on the seed
rate chart.
10. On the console, select the new Material, seed
disk Cell Count, and target population.
68908
2
1
3
!
68589
2
1
68909
1
68911
2
Summary of Contents for PL5200
Page 12: ...Great Plains 411 825M 12 07 2020 5 PL5200 Planter Table of Contents Index Safety Information ...
Page 62: ...Great Plains 411 825M 12 07 2020 55 PL5200 Planter Table of Contents Index Adjustments ...
Page 66: ...Great Plains 411 825M 12 07 2020 59 PL5200 Planter Table of Contents Index Options ...
Page 78: ...Great Plains 411 825M 12 07 2020 71 PL5200 Planter Table of Contents Index Maintenance ...
Page 86: ...Great Plains 411 825M 12 07 2020 79 PL5200 Planter Table of Contents Index Troubleshooting ...
Page 96: ...Great Plains 411 825M 12 07 2020 89 PL5200 Planter Table of Contents Index Specifications ...
Page 106: ...Great Plains 195 612M 12 07 2020 99 26 Foot 2 Section Drill Table of Contents Index Warranty ...
Page 108: ...Great Plains 411 825M 12 07 2020 101 PL5200 Planter Table of Contents Index ...
Page 109: ...Table of Contents Index ...
Page 110: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 ...