NP30A or NP40A
Applicator Operating Instructions
65
2019-03-11
407-502M
Folding 2013+ 5-Section
These instructions presume that the applicator is
unfolded and lowered.
1. Verify that the wing lock pins (page 47) are not in the
wing rest cradles. Typically they are in storage tubes.
2. Set the Fold switch to
FOLD / UNFOLD.
Electrocution and Overhead Collision Hazards:
Do not fold with switch in FIELD position. In FIELD, the
outer wing sections cannot fold. The folded applicator would
be over 21 feet (6.2 m) high. This dramatically increases the
risk of electrocution from overhead lines, with or without
direct contact. It is also too high for safe transport.
3. Raise the hitch.
4. Retract the fold/lift circuit to simultaneously raise and
fold the applicator. Observe the fold sequence. Lift
and fold do not start and end at the same time.
If an abnormal fold is detected, set the fold/lift circuit
to Retract, then Neutral at wings level. Troubleshoot
the problem.
5. Set the fold/lift circuit to Neutral.
6. Remove spacers (page 38). Install lift-assist cylinder
7. Insert wing lock pins (page 47).
8. Extend fold/lift to lower lift-assist cylinders onto lock
channels. Set fold/lift circuit to Float. Shut off tractor.
For parking/storage/service, lower the applicator onto
parking stands.
Figure 47
Switch for Fold
34918
Figure 48
Normal Fold Sequence
34921
Figure 49
Abnormal Fold
34923