![GREAT PLAINS 3P1006NT Operator'S Manual Download Page 92](http://html.mh-extra.com/html/great-plains/3p1006nt/3p1006nt_operators-manual_2259420092.webp)
2018-06-06
151-144M
3P1006NT
Appendix B - Pre-Delivery
88
Attach Meter Hoses at Rows
All meter hoses are shipped disconnected at the row
units. Clamps are shipped inside a seed box. The opener
frame has openings for up to three material hoses:
•
The forward hole
is always used for the seed
delivery tube for the main seed box.
•
The center hole
is used for Dual Seed, Fertilizer or
Native Grass, if installed.
•
The rear hole
is used for Small Seeds, if installed.
Start with the left row unit (row 1). For each row:
Main Seed Hose
Select one:
Open the clamp
. Place it onto the outlet end of the
hose
, up against the ribs. Slide the outlet end of the
hose fully onto the seed tube inlet
at the forward row
unit opening
. Move the clamp to just below the raised
lip of the seed tube inlet.
Dual Seed or Fertilizer Hose
Select one:
Open the clamp
. Place it onto the outlet end of the
hose
, up against the ribs. Slide the outlet end of the
hose fully onto the delivery tube inlet
at the center
row unit opening
. Move the clamp to halfway onto the
hose neck.
Native Grass Hose
Select one:
Open the clamp
. Place it onto the outlet end of the
hose
, up against the ribs. Slide the outlet end of the
hose fully onto the native grass tube inlet
at the
center row unit opening
. Move the clamp to halfway
onto the hose neck.
Small Seeds Hose
Select one:
Open the clamp
. Place it onto the outlet end of the
hose
, up against the ribs. Slide the outlet end of the
hose fully onto the small seeds tube inlet
at the rear
row unit opening
. Move the clamp to halfway onto the
hose neck.
Figure 65
Seed and Fertilizer Hoses
32683
f
c
r