3N-40P
Adjustments
89
2019-03-14
196-538M
10 and 20 Series Meter Wheel Replacement
Applies only to 10 and 20 Series openers. See
page 80 for 10HD and 25 Series.
Choose the correct seed meter wheel for the type of
seed you will be using. Be sure to use the same wheel
type on all meters.
Meter Wheels Not Interchangeable:
Seed meter wheels for the 20 Series row units are made of a
black color material and are not interchangeable with the
other Great Plains seed meter wheels for other machines. Use
only black wheels in 20 Series row units.
1. Clean out meter. For more information, see
2. Push in spring-loaded wheel retainer and make
1
/
4
turn.
3. Pull off wheel retainer and spring.
4. Pull the seed meter wheel out about
1
/
4
inch (6 mm),
and spin backward to clean out seeds from top
pockets.
5. Remove seed meter wheel using finger holes in
wheel face.
Figure 112: 20P:
Singulator Wheel Retainer
27459
Figure 113: 20P:
Remove Retainer and Spring
27460
Figure 114: 20P:
Remove Meter Wheel
27461