GRAUPNER LiPo Balancer Plus Operating Manual Download Page 1

Best.-Nr. 

3064

Order-No.

3064

Rèf. No. 

3064

BEDIENUNGSANLEITUNG

OPERATING MANUAL

INSTRUCTIONS D´UTILISATION

LiPo Balancer Plus

Die Ultra-Präzise Microcontroller gesteuerte SMD Elektronik sorgt

für minimalste Spannungsdifferenzen und bietet das Maximum an Sicherheit!

The ultra precious microcontroller supervised SMD electronic provides

minimal voltage differences and offer maximal safety.

Le micro-contrôleur ultra-précis qui pilote l’électronique SMD assure des différences de 

tension minimales et offre un maximum de sécurité

Seite 2

page 8

page 14

G R A U P N E R GmbH & Co. KG   D - 7 3 2 3 0   K I R C H H E I M / T E C K   G E R M A N Y

Keine Haftung für Druckfehler!   Änderungen vorbehalten!

PN.JL-01

Summary of Contents for LiPo Balancer Plus

Page 1: ...imum an Sicherheit The ultra precious microcontroller supervised SMD electronic provides minimal voltage differences and offer maximal safety Le micro contr leur ultra pr cis qui pilote l lectronique...

Page 2: ...eignetes Ladeger t anzuschlie en Verwenden Sie nur Original kabel Aus Sicherheitsgr nden sind Umbau ma nahmen am Ein und Ausgang zu unter lassen Das Ladeger t der LiPo Balancer Plus und die zu ladende...

Page 3: ...nung von 3 6V Zelle geeignet Lithium Akkus zeichnen sich vor allem durch ihre im Vergleich zu anderen Akkutypen wesentlich h heren Energiedichte aus Dieser wesentliche Vorteil auf der einen Seite erfo...

Page 4: ...ossen ist Dadurch ist der Eingang auch Kurzschlussge sch tzt 4 Inbetriebnahme Inbetriebnahme berladeschutz durch berspannungsab schaltung Wenn eine Zelle die Spannung von 4 26V er reicht wird der Lade...

Page 5: ...llenz hler LEDs F r jede angeschlossene LiPo Zelle ist der LiPo Balancer Plus mit einer LED ausgestattet Die entsprechende LED sig nalisiert durch blinken sobald ausbalanciert wird Die Zellen 1 3 5 be...

Page 6: ...n Ger ten ab gegeben werden Die Werkstoffe sind gem ihrer Kennzeichnung wiederverwertbar Mit der Wiederverwendung der stofflichen Verwertung oder anderen Formen der Verwertung von Altger ten leisten S...

Page 7: ...Ladeger t verbunden werden 10A Sicherung Einzelzellen AUSGANG F r den Anschluss des mehrpoligen GRAUPNER LiPo Messkabel AUSGANG F r den Anschluss des Hochstromsteckers Ihres LiPo Akkus Es darf nur ein...

Page 8: ...not to modify the inputs and outputs of the device in any way The charger and the battery to be charged should be set up on a heat resistant non inflammable and non conductive surface before use Never...

Page 9: ...her energy density However this important advantage is balanced by increased risks and it is necessary to adopt different charging and discharging methods in order to reduce the risk to a minimum It i...

Page 10: ...ected 10 Using the balancer for the first time Using the balancer for the first time Overcharging protection over voltage cut off If a cell reaches the voltage of 4 26 V the charge process is immediat...

Page 11: ...u must set the balancer to Disconnect Mode Cell count LEDs The LiPo Balancer Plus is fitted with an LED corresponding to each LiPo cell connected to the unit The appropriate LED flashes to indicate th...

Page 12: ...for recycling electrical and electronic equipment Individual markings indicate which materials can be recycled and re used You can make an important contribution to the protection of our shared enviro...

Page 13: ...PNER multi pin LiPo measuring lead OUTPUT for connection to the high current connec tors of your LiPo battery Only one of the two connector sets may be used STATUS LED MODE RESET A brief summary of th...

Page 14: ...raccord un chargeur adapt pour les l ments au Lithium Polymer Utiliser uniquement le cordon original pour le connecter Durant le processus de charge le chargeur le LiPo Balancer Plus et la batterie c...

Page 15: ...s accus au Lithium se distinguent surtout par leur capacit beaucoup plus lev e par compa raison aux autre types d accus Ce gros avantage exige cependant un traite ment diff rent en ce qui concerne la...

Page 16: ...ervice Mise en service Protection en surcharge par coupure de sur tension Lorsqu un l ment atteint une tension de 4 26 V le processus de charge sera interrompu imm diatement avant une surcharge pour l...

Page 17: ...bre d l ments Le LiPo Balancer Plus est qui p d un LED pour chaque l ment LiPo connect Le LED correspondant signalera en clignotant d s qu il sera qui libr Les l ments 1 3 5 comprennent un LED rouge l...

Page 18: ...que ce produit ne devra pas tre jet dans une poubelle domestique normale la fin de sa dur e de vie Il devra tre d pos dans un container sp cial pour le recyclage des appareils lectriques et lectroniqu...

Page 19: ...r Fusible 10 A SORTIE des diff rents l ments Pour le raccorde ment de la prise multip les du cordon de mesure LiPo GRAUPNER SORTIE Pour le raccor dement de la prise haute tension des accus LiPo Un seu...

Page 20: ...d s de l usure de la surcharge de mauvais accessoires ou d une application inadapt e sont exclus de la garantie Cette garantie ne remet pas en cause les droits et pr tentions l gaux du consommateur A...

Reviews: