Before getting started
6
PVS 3000 & 3500 Series Installation Guide
System power-off and reboot procedure
When you power-off or reboot your Profile XP Platform and RAID storage system,
you must follow the proper sequence as described in the following procedure.
NOTE: If your Profile XP Media Platform is part of an Open SAN, disregard this
procedure, and refer to the instructions in the Open SAN Instruction Manual for
shutting down the Open SAN.
1. Power-off the RAID storage system by powering-off the RAID Controller chassis
prior to, or at the same time as the RAID Expansion chassis.
2. Wait approximately 30 seconds for the disk drives to spin down, then power-on all
RAID Expansion chassis, then all RAID Controller chassis. Always power-on the
RAID Expansion chassis prior to, or at the same time as the RAID Controller
chassis.
3. Wait for RAID storage initialization, as follows:
- PFR700 RAID Storage systems - Wait until all disk access LEDs are steady —
approximately 4 minutes. The controller READY LED must be ON, the front
Power LED must be ON, and the front Service LED must be OFF. (Refer to the
PFR 700 Instruction Manual to interpret other disk access LED or status LED
behavior.)
- PFR600 RAID Storage systems - Wait until all disk access LEDs are steady
green— approximately 4 minutes. The rear panel 7-segment LED displays the
chassis address. (Refer to the PFR 600 Instruction Manual to interpret other disk
access LED or 7-segment LED behavior.)
On the Profile XP Media Platform, shut down and restart the Windows operating
system. Wait for auto-logon as described in “Start your system” on page 13.
Summary of Contents for Profile XP PVS3000
Page 14: ...Start your system 14 PVS3000 3500 Series Installation Guide 23 July 2004 ...
Page 20: ...Create a video file system 20 PVS3000 3500 Series Installation Guide 23 July 2004 ...
Page 26: ...Set up PFR600 network settings 26 PVS3000 3500 Series Installation Guide 23 July 2004 ...
Page 46: ...46 PVS3000 PVS3500 Installation Guide 23 July 2004 ...