154
Procedures
Black Calibration
• recommended: when the ambient temperature changes by more than 20 °C / 36 °F.
+ ✎
Tip
The best results are achieved when camera settings and calibration conditions are similar to
the intended shooting situation, for example, shortly before a shooting.
How to apply
To start the Black Calibration procedure proceed as follows:
• Switch on power and camera and wait for the system to become fully operational. To
ensure the best black performance, wait until the camera has reached its operational
temperature. This may take up to 30 minutes, depending on the ambient temperature.
+
Note
+ ☞
Note
The user level must be set to
Service
to access the Service menu.
Do not change Camera mode, Video mode and do not interrupt reference/locking during
the calibration procedure.
• In the camera menu, go to the
Service > Calibrations > Black Calibr
menu and select
the calibration temperature using the
Calibr Temp
item. There are two options:
37 C
(default) or
Act
(actual) temperature.
• Go to the
Black Cal
item and select it. The camera starts to warm up or cool down,
depending on the ambient temperature and the selected calibration temperature. The
lens is capped automatically and lens iris is closed during the calibration process. The
Actual (current) temperature can be monitored using the
Act Temp
item.
• When the camera reaches the selected calibration temperature, the Black Calibration
process starts. It takes up to 80 seconds to complete. During the process, you can
monitor Black Calibration using the
status
item and a progress indication (%) is shown
in the viewfinder.
• When the process is finished, the camera can be used normally.
+
Note
+ ☞
Note
It is recommended to carry out Black Calibration when the camera is used under extreme
ambient temperature conditions. Make sure to set the
Calibr Temp
item to
Act
before
performing the calibration.
The results of the Black Calibration procedure are stored in the camera’s internal memory.
The new values are used after switching the camera off and on.
Black Calibration affects all video modes within one of the following clusters of video
modes: (720p, 1080i and 1080p in single speed), (720p, 1080i and 1080p in 3X speed) and in
4K video modes. The availability of video modes depend on installed licenses.
Summary of Contents for LDX 150
Page 1: ...www grassvalley com LDX 150 Live Production Camera User Guide 13 00126 000 v1 0 2022 11 15 ...
Page 12: ...xii Notices ...
Page 18: ...xviii Table of Contents ...
Page 22: ...4 Introduction System components and accessories ...
Page 40: ...22 Configuration XCU mode 1X speed UHD with XCU Universe UXF ...
Page 58: ...40 IP Media setup PTP tab ...
Page 104: ...86 Video setup Reverse Scan ...
Page 162: ...144 Connectors C2IP Ethernet connector ...
Page 174: ...156 Procedures Updating camera software ...
Page 180: ...162 Installation of Q SFP modules List of Q SFP modules ...
Page 184: ...166 Specifications Dimensions ...