LDK 4488, LDK 4489 SuperXpander/Xpander User’s Guide (v6.0)
41
Chapter 6 - Connectors
6.2 Right side panel
6.2.1 Mains power connector
6.2.2 Script light connector
VF C
onn.
V
i
ew
fi
nder
OUT
V
i
ew
fi
nder BNC
Ext
Pb
Y
Pr
100 - 240V~ 50-60Hz 3A
T4AH 250V
Loc
a
l
Power
Act
i
ve
Scr
i
pt
L
i
ght
Power
12V - 6VA
O
ff
On
viewfinder
connector
script
light
connector
mains
power
connector
component
viewfinder
outputs 3x *)
CVBS
viewfinder
output *)
Triax or fiber
connection
to camera
*) Available on LDK 4488/00
and LDK 4489/00 only.
Mains input voltage: 100 to 240 VAC
(auto ranging)
Mains frequency: 50 to 60 Hz
Fuses (2): T4.0 A H250V
3-pin IEC-320
male connector
Pin
Description
1
Neutral
2
Phase
3
Earth
2
1
3
Fischer 3-pin female
connector
Pin
Description
1
+12 V
DC
(max. 6 W)
2
GND
3
Shield
3
1
2
NOTE: the script light connector is
different than the one on the camera
adapter!
Manufacturer/type: Fischer DBP 103
A052-28