background image

3922 496 31851 October 2011 v1.0

LDK 4425

User’s Guide

3G Fiber Power Converter

Summary of Contents for LDK 4425

Page 1: ...3922 496 31851 October 2011 v1 0 LDK 4425 User s Guide 3G Fiber Power Converter ...

Page 2: ...r a class A digital device pursuant to part 15 of the FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this product in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference Copyrig...

Page 3: ...Operation 2 1 Indicator panel 15 2 2 Power and connection 16 2 2 1 Local power indicator 16 2 2 2 Camera test camera connected indicators 16 2 2 3 Base station power indicator 17 Chapter 3 Specifications 3 1 Technical specifications 19 3 1 1 General 19 3 1 2 Dimensions 20 3 2 Connectors 20 3 2 1 Mains power connector 20 3 2 2 Dark Fiber connectors 2x 21 3 2 3 Hybrid Fiber connector 21 ...

Page 4: ...ology This program accepts any Grass Valley branded equipment Upon request a Certificate of Recycling or a Certificate of Destruction depending on the ultimate disposition of the product can be sent to the requester Grass Valley will be responsible for all costs associated with recycling and disposal including freight however you are responsible for the removal of the equipment from your facility ...

Page 5: ...y your Grass Valley sales or service centre within eight days If the shipping container shows signs of damage or stress notify the carrier as well If the unit is being returned to Grass Valley for servicing try to use the containers and materials of the original packaging Attach a tag indicating the type of service required return address model number full serial number and the return number which...

Page 6: ...st be observed Whenever it is likely that safe operation is impaired the apparatus must be made inoperative and secured against any unintended operation The appropriate servicing authority must then be informed For example safety is likely to be impaired if the apparatus fails to perform the intended function or shows visible damage Read and comply with the warning and caution notices that appear ...

Page 7: ...power the unit from the building s installation overvoltage CAT II The unit is not designed to be powered directly from a mains distribution net Cautions Cautions indicate procedures or practices that should be followed to prevent damage or destruction to equipment or property Do not subject the unit to severe shocks or vibration Do not expose the unit to extremes of temperature To prevent risk of...

Page 8: ... means that splashing against the enclosure from any direction shall have no harmful effect However to prevent damage or injury take the following precautions To prevent rain from entering the mains entty only use the unit in its default horizontal position Always unplug the mains plug before a wet or moist plug is disconnected from the unit When not in use always protect connectors with their dus...

Page 9: ...ay result in hazardous radiation exposure To ensure proper use of this product please read this instruction manual carefully and retain for future reference Should the unit ever require maintenance contact an authorized service location Fiber optic cable precautions Fiber optic cables and connectors are easily damaged take the following percautions into account Do not bend the cable beyond the min...

Page 10: ...sleeves and the interior and exterior of connector shells For plugs the interior surfaces of alignment sleeves and the tips of ferrules are to be cleaned with a cleaning stick treated with the appropriate fluid Cleaning sticks with a slender design are available that allow alignment sleeves to be cleaned without having to detach them For jacks it is important to clean both the tips and sides of th...

Page 11: ...wing code GREEN and YELLOW EARTH BLUE NEUTRAL BROWN LIVE As the colors of the wires in the mains lead of this apparatus may not correspond with the colored markings identifying the terminals in your plug proceed as follows The wire colored GREEN and YELLOW must be connected to the terminal on the plug marked with the letter E or by the safety earth symbol or colored GREEN or GREEN and YELLOW The w...

Page 12: ...12 LDK 4425 3G Fiber Power Converter User s Guide v1 0 ...

Page 13: ...he LDK 4420 3G Twin Base Station and the LDK 5420 3G Fiber adapter The unit routes dark fiber signals coming from the LDK 4420 3G Twin Base Station to Hybrid Fiber signals and adds power 1 2 Versions The following versions of the 3G Fiber Power Converter are available Version Fiber Base Station Hybrid Fiber Camera LDK 4425 00 SC Fischer LDK 4425 05 SC Lemo LDK 4425 10 ST Lemo ...

Page 14: ...iber Power Converter User s Guide v1 0 Chapter 1 Installation 1 3 Location of connectors and indicators Hybrid Fiber Connector Indicator panel Mains connector Dark Fiber connectors multiple options available Earth pin ...

Page 15: ...ter 2 Operation Chapter 2 Operation 2 1 Indicator panel The indicator panel gives an overview of power and connection information BS PWR LOC PWR CAM TST CAM CON Local Power indicator Camera Test indicator Base station power indicator Camera connected indicator ...

Page 16: ...s not used LOC PWR CAM TST CAM CON LOC PWR CAM TST CAM CON Indicators Condition Indicators Condition CAM CON green flashing Transmission cable is connected to camera CAM TST red Transmission cable error shortcircuit or wrong power system CAM CON green Transmission cable is connected to camera and camera is powered CAM TST yellow Camera power is switched off by a control panel or from a menu CAM TS...

Page 17: ...peration 2 2 3 Base station power indicator This green indicator lights when base station power is used to power the camera Indicators Condition Indicators Condition BS PWR green Base Station power is in use BS PWR off Base Station power is in not in use BS PWR BS PWR ...

Page 18: ...18 LDK 4425 3G Fiber Power Converter User s Guide v1 0 Chapter 2 Operation ...

Page 19: ...x L 250 x 194 x 480 mm 9 8 x 7 6 x 18 9 in Weight approx 8 5 kg 18 7 lbs Operating temperatures 20 to 45 C 4 to 113 F Storage temperatures 25 to 60 C 13 to 140 F Power requirements 100 to 240 VAC 47 to 63 Hz Power consumption max 400 W Power connection IEC type 3 pin male Fiber connector multiple options Fiber cable length Depending on connectors and optical budget ...

Page 20: ...er Converter User s Guide v1 0 Chapter 3 Specifications 3 1 2 Dimensions 3 2 Connectors 3 2 1 Mains power connector 480 mm 250 mm 194 mm Fuses 2x 8AT 250 VAC Pin Description 1 Neutral 2 Line 3 Earth 3 1 2 IEC style 3 pin male ...

Page 21: ...nectors 2x 3 2 3 Hybrid Fiber connector A B Cn Description A Optic fiber A B Optic fiber B Various types available Lemo hybrid fiber connector compliant with SMPTE 304M Pin Description 1 Optic fiber channel A 2 Power supply return 3 Optic fiber channel B 4 Power supply 1 4 2 3 Various types available ...

Page 22: ...22 LDK 4425 3G Fiber Power Converter User s Guide v1 0 Chapter 3 Specifications ...

Page 23: ...LDK 4425 3G Fiber Power Converter User s Guide v1 0 23 ...

Page 24: ...Printed in The Netherlands Copyright Grass Valley Nederland B V 2011 ...

Reviews: