Binding Hot Spare drives
Prerequisites are as follows:
•
You must access Storage Utility (via the K2 System Configuration application login) with
permissions equivalent to K2 administrator or higher.
•
When you access Storage Utility, the K2 SAN must be offline.
•
All iSCSI clients and K2 clients in the K2 SAN must be shut down.
You can bind disks as hot spare drives. Hot spare drives are on standby and are used in the event of
a drive failure in a RANK. If a drive fails, the RAID Controller automatically selects a hot spare
drive to use in place of the failed drive. This prevents the system from operating in a degraded state.
If the drives you want to designate as hot spares are bound as part of a RANK, you must unbind the
drives first, then bind them as hot spares. To function as a Hot Spare, the drive must be at least as
fast and have at least as much capacity as the failed drive it replaces.
1. In Storage Utility, right-click the
Unbound
node for a controller, then select
Bind
in the context
menu. (Peer controllers that share the same set of disks are automatically selected as a pair.)
The Binding dialog box opens showing all unbound disks for the controller listed in the Available
Disk list.
2. Select
Hot Spare
using the BIND TYPE drop-down box.
3. In the Available Disks box, select the disk(s) to be used as hot spares, then click the add (arrow)
button to add them to the Selected Disks list.
NOTE: As an aid in identifying a disk module’s physical location, select it in the Selected
Disks list, then click
Identify Disks.
This causes the disk drive LED to flash.
4. Click
OK
to close the Binding… dialog box and begin the binding process. The Progress Report
dialog box opens, showing the status of the binding process.
5. Upon 100% completion, click
Close
in Progress Report window.
6. Restart the K2 Media Server.
Loading K2 10Gv2 RAID controller and expansion chassis microcode
The K2 10Gv2 RAID controller must be connected to the control network to support the operations
in this topic.
You might be instructed in K2 Release Notes to upgrade the RAID Controller microcode and/or
expansion chassis on the RAID chassis. This allows you to take advantage of the RAID enhancements
and benefit from improved reliability.
1. If upgrading expansion chassis microcode, take the RAID system offline.
316
K2 SAN Installation and Service Manual
2014 01 27
Administering and maintaining the K2 SAN
Summary of Contents for K2 SAN
Page 2: ......
Page 4: ......
Page 28: ...28 K2 SAN Installation and Service Manual 2014 01 27 Preface ...
Page 234: ...234 K2 SAN Installation and Service Manual 2014 01 27 Configuring clients on the K2 SAN ...
Page 239: ...2014 01 27 K2 SAN Installation and Service Manual 239 Operating the K2 SAN ...
Page 248: ...248 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Page 346: ...346 K2 SAN Installation and Service Manual 2014 01 27 Index ...