The restart of the K2 Media Server after it is configured is complete
This task is required for NAS server functionality.
1. Verify that the K2 Media Server has restarted by opening the MS-DOS command prompt and
use the “ping” command.
2. In the K2Config application tree view, under the K2 Media Server select the File System Server
node.
The File System Server Configuration page appears.
3. Click
Check
and verify that the V: drive is shared.
The K2 Nearline SAN configuration is complete.
Configuring the redundant nearline K2 SAN
Work through the topics in this section sequentially to configure a redundant nearline (Tier 3) K2
SAN.
Prerequisites for initial configuration - Nearline K2 SAN
Before beginning your initial configuration, make sure the devices of the K2 SAN meet the following
prerequisites.
Control point PC
•
Ethernet cable connected
•
Control Point software installed
•
Control network IP address assigned
•
Network communication over the control network with all other K2 devices
•
Power on
Ethernet switch
•
Ethernet cables connected
•
Control network IP address assigned
•
VLANs set up
•
Trunks set up
•
Power on
K2 Media Server
•
Ethernet cables connected
•
Fibre Channel cable connected
•
Redundant servers connected by serial cable
•
Software installed, as from the factory, including QuickTime 7
02 February 2012
K2 SAN Installation and Service Manual
205
Configuring and licensing the K2 SAN
Summary of Contents for K2 BASECAMP EXPRESS
Page 28: ......
Page 38: ......
Page 62: ......
Page 112: ......
Page 124: ......
Page 248: ...248 K2 SAN Installation and Service Manual 02 February 2012 Operating the K2 SAN ...
Page 256: ......
Page 340: ......
Page 354: ......
Page 366: ...366 K2 SAN Installation and Service Manual 02 February 2012 Index ...