![GRASS VALLEY HCO-3931 User Manual Download Page 57](http://html1.mh-extra.com/html/grass-valley/hco-3931/hco-3931_user-manual_2257615057.webp)
USER MANUAL
HCO-3931 |
57
Alarm Config Panel
This panel is used to configure the alarm reporting of the HCO-3931 application. The panel opens in a new window
when the button is clicked and can be resized.
Figure 39
Alarm Configuration
Status/Name
This column contains an expandable tree listing all the alarms reported by this HCO-3931 card.
Each alarm name includes an icon that shows its current status.
Some alarms may be text-only, and the alarm status is shown in the name and not by a status icon.
Card LED
,
Overall Alarm and GSM Contribution
These columns contain pulldown menus used to set the severity level of each individual alarm to the
alarm named in the column heading. This can be set independently for Card LED, Overall Alarm and
GSM Contribution.
Card LED
This column is used to set the severity level of the selected individual alarm to the status LED located on the front
card-edge. The Card LED status is shown at the bottom of the alarm tree in the Status/Name column. If at least one
Critical or Major alarm is triggered, the LED will change to red. If no Critical or no Major alarms are triggered and
Minor alarms are occurring, the LED will change to yellow.