GV K-Frame
XP
55
The Single Module Satellite Panel has internal module cabling the same as the other
Stripes. Simply plug the module into a port using the provided cable.
The Double Module Satellite Panel has a similar internal cabling arrangement, but one
cable passes through a hole to the other tray.
Kayenne Touch Screen Menu Panels (Used with PCU)
Connect a single or primary Menu Panel to the PCU Menu 1 connector, using the supplied
custom multi-pin cable. Connect an optional second Menu Panel to the Menu 2 connector.
Menu Panels are assigned to suites during system configuration.
System Cabling for the Karrera Control Panel
The Karrera switcher system uses Ethernet, serial, DVI, and USB connections for system
communications.
RS-422/485
GPI In/Out
Tally
USB
Keyboard, VGA
RS-232
Isolate Switcher System from External Network
Karrera
GV K-Frame XP System Communications Overview
Karrera Suites and Control Surfaces
The GV K-Frame XP Control Panel system flexibility allows you to locate control surfaces in
physically separate locations. Two dedicated, customer supplied Ethernet switches may be
required when multiple suites are being used.
PC
7
Internal Control
Laptop
Ethernet
VGA
Ethernet
Switch
Eht
er
ne
t Sw
itc
h
8875_16_r1
CAUTION: The facility network used for your
GV K-Frame XP
system
(and other video production equipment) should be kept
separate from any external network, to prevent network
traffic from adversely affecting system operation.
Summary of Contents for GV K-FRAME XP
Page 1: ...GV K FRAME XP VIDEO PRODUCTION FRAMES Installation Planning Guide 13 06166 000AB 10 15 21 ...
Page 18: ......
Page 40: ...Frame Installation 40 15RUVideo Processor Views 15 RU Front View withDoor Removed ...
Page 41: ...GV K Frame XP Installation Planning Guide 41 15 RU Rear ViewIP Gearbox Conversion ...
Page 43: ...GV K Frame XP Installation Planning Guide 43 PowerSupplyFrameDimensions TopView ...