Output Monitoring
Selecting No Matrix Status Text
To be notified of Matrices going off line and select what status text is dis-
played (
NoMatri
x or
Undef
):
1.
Log on to the Router Controller OUI and go to the
Options
screen.
2.
Turn ON the
Process matrix offline
flag.
•
Turn ON the
Report NoMatrix
flag to see status as
NoMatrix
.
•
Turn OFF the
Report NoMatrix
flag to see status as
Undef
.
Turn OFF the
Process matrix offline
flag to see the previously taken Source as
the status of Destinations (the previous system behavior).
shows these flags on the Router Controller Options screen.
Output Monitoring
Note
Before attempting to configure the Encore for monitoring, monitor wiring and
switch settings for the particular router must be understood and completed.
Please refer to the installation manual for the specific router for more infor-
mation.
A monitoring system is used to check switcher performance by switching
the output signal of interest to a quality control station. When configured
for output monitoring, the control panel will automatically switch its con-
trolled Destination to the Monitor output.
See
Summary of Contents for Encore
Page 1: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 3: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Page 14: ...14 Encore Configuration Manual Contents ...
Page 36: ...36 Encore Configuration Manual Section 2 Encore Fundamentals ...
Page 54: ...54 Encore Configuration Manual Section 3 Encore OUI Description ...
Page 284: ...284 Encore Configuration Manual Section 6 Control Panel Configuration PMB Paging MultiBus XY ...
Page 382: ...382 Encore Configuration Manual Section 8 Additional OUI Operations ...
Page 406: ...406 Encore Configuration Manual Section 9 System Manager Reference ...