92
APEX — Installation and Service Manual
Section 3 — Installation
Output Card Switches
•
S1 through S4
•
S7 through S10
•
S13 through S16
•
S19 through S22
•
S25 through S28
These switches are enabled by S34-8 as described above. Switch settings are
the same as those shown for S28 5-6 in the CX-34000 drawing in
Input Card Switches
•
S5 and S6
•
S11 and S12
•
S17 and S18
•
S23 and S24
•
S29 and S30
These switches, when S34-8 is OFF, can be used to select the MADI refer-
ence on a board-by-board basis. The settings are the same as those shown
for S30 7-8 in
S31 (LIN NUM / VREF)
These switches are not used.
S32 (SR AREF/VREF)
These switches are not used.
AES / Video Reference Selections
Each output board provides a block of 32 outputs and by factory default all
blocks are assigned to reference 00, which corresponds to the VID REF A
connector on the rear panel.
Each input board provides a block of 32 inputs and by factory default all
blocks are assigned to reference 00, which corresponds to the VID REF A
connector on the rear panel.
If redundant Matrix boards are installed, the same reference must be pre-
sented to both REF A and REF B connectors, the system will automatically
operate the Matrix boards as a redundant pair. See
and
Dual References - Redundant Operation
for examples.
Summary of Contents for APEX -
Page 4: ...4 APEX Installation and Service Manual ...
Page 6: ...6 APEX Installation and Service Manual ...
Page 10: ...10 APEX Installation and Service Manual Contents ...
Page 12: ...12 APEX Installation and Service Manual Preface ...
Page 28: ...28 APEX Installation and Service Manual Regulatory Notices ...
Page 70: ...70 APEX Installation and Service Manual Section 2 Planning Guide ...
Page 108: ...108 APEX Installation and Service Manual Section 3 Installation ...
Page 116: ...116 APEX Installation and Service Manual Section 4 Troubleshooting ...