8960DEC Instruction Manual
17
Configuration
VBI Line Processing
VBI Processing
VBI/Data Line
Processing/
VBI Processing
1/C N/A
Delete,
Notch Decode or
Video to Luma
Notch Decode
Select Notch Decode or Video to
Luma filtering or Delete to remove
content (lines 10-20 NTSC, lines
6-25 PAL-B).
Data Line Processing (Active Picture lines available for use as data lines determined by SAV setting)
Data Line
Processing
VBI/Data Line
Processing/
Data Line Processing
2/C
N/A
Delete or
Notch Decode
Notch Decode
Select Notch Decode to apply U/V
filtering or Delete to remove con-
tent (blank).
Setup on Data
Lines (525 only)
VBI/Data Line
Processing/
Data Line Processing
2/D
N/A
Setup or
No Setup
No Setup
Select Setup if Setup is present
on data lines or No Setup for no
setup present.
Video Timing and Freeze Controls (available only when Frame Sync Submodule option is installed)
Lock Source
Timing/
Lock Source
2/0
N/A
Video Input or
Reference
Reference
Choose a lock source.
Horizontal Phase
Timing/
Horizontal Delay
2/2
H Phase
0–63418 ns (525)
0–63862 ns (625)
(step size 37 ns)
0
Adjust horizontal delay in clock
increments.
Vertical Phase
Timing/
Vertical Delay
2/3
V Phase
0–524 lines (525)
0–624 lines (625)
(step size 1 line)
0
Adjust vertical delay in line incre-
ments.
Freeze
Recognition
Timing/
Freeze Recognition
2/4
N/A
Manual or
Auto
Manual
Select Manual or Auto. Auto
stores the last field in the frame
synchronizer to use if the input
video is lost or corrupted.
Manual Freeze
Timing/
Freeze Button
2/5
N/A
On or
Off
Off
Perform a manual freeze accord-
ing to selected freeze parameters.
Freeze Mode
Timing/
Freeze Mode
2/6
N/A
Field or
Frame
Frame
Select freeze mode as Frame or
Field.
Freeze Field
Timing/
Freeze Field
2/7
N/A
Field 1 or
Field 2
Field 1
Select freeze field as Field 1 or
Field 2.
Freeze Signal
Timing/
Freeze Signal
2/8
N/A
Black or
Last Field
Last Field
Select the freeze output signal if
Auto or Manual Freeze is acti-
vated.
Table 4. Summary of 8960DEC Configuration Functions By Function
Function
Web Page
Function Name
Rotary
Switch
Bank/Setting
Control
Panel
Mnemonic
Range/Choices
Default
Value
Description