This module can be mounted in a GeckoFlex 
frame when ordered with the 8900V-R GeckoFlex 
Video rear module.

8937 

SDI/ASI reclocking equalizing distribution amplifier

This distribution amplifier is ideal for medium- 
to long-distance distribution of digital signals. 
It is fully DVB ASI compatible so it can be used 
in any application where standard SDI video or 
ASI signals are to be copied and distributed. 
The standard reclocker circuit greatly reduces 
jitter induced over long cable runs or from 
unstable sources of standard data rate signals. 
The reclocker can easily be disabled to pass 
SMPTE 310M and other non-standard data 
rate signals. A user-enabled video presence 
detection feature generates SNMP traps that 
can be sent to our NetCentral SNMP manager 
or other SNMP systems.

Key Features

Passive differential looping input with 

• 

eight active outputs
 Suitable for SMPTE 310M, SMPTE 259M, 

• 

DVB ASI, SDI 270 Mb/s plus most other 
800

 

mV data from 4 Mb/s to 360 Mb/s

Input presence detection with SNMP trap 

• 

generation 
 Reclocking circuit eliminates jitter 

• 

Automatic input cable equalization for up 

• 

to 300 meters
Card edge LEDs status indicators 

• 

Supported Frame Types

GeckoFlex with 8900V-R GeckoFlex Video rear module, 
Gecko video frames: 8900TX-V, 8900TF-V, 8900TFN-V 

Power Rating

3 Watts – single slot 

Input

Type: 

800 mV ±10% serial digital data including 

SMPTE 259M

Connector type:

 BNC

Impedance:

 High Z differential loop-through

Supported data rates: 

4 Mb/s through 360 Mb/s 

Reclocked data rates: 

143, 177, 270, 360 Mb/s

Return loss: 

>15 dB (up to 360 MHz)

Auto equalization: 

Up to 300 meters (270 Mb/s)

Output

Type:

 800 mV serial digital data in phase with the 

input signal

Number of outputs: 

Eight active plus one passive 

loopthrough 

Connector type:

 BNC

Impedance: 

75Ω

Return loss: 

>15 dB (up to 360 MHz)

Performance

Electrical length: 

<20 ns

Temperature range: 

0° – 45°C

Local Indicators/Controls

LED indicators:

• Signal presence
• Input sample rate

User controls: 

• Bypass/auto jumper selection for reclocker
• Local/local-remote control enable jumper   

Remote: 

SNMP trap generation – input presence 

detection

8937 

SDI/ASI Reclocking Equalizing Distribution Amplifier

For detailed specifications, installation, and setup 
instructions see:
www.grassvalley.com/docs/modular