18
4. Tools Setting [TOOL]
In the main screen ( page 9), click [TOOL] to open the [Tools Setting] screen.
In the [Tools Setting] screen, you make advanced settings for the behavior of the tool and
how plotting data is processed.
1
Step Pass
Set the units by which data is processed. Normally, set the value to [1].
What is Step Pass (page 19)
Setting range 0 to 20
2
Offset Force
Specify the cutting force when the direction of the blade is set in the
initial operation. The value is also used as the cutting force when
blade rotation control is performed when tangential mode is used.
Setting range 1 to 31 (CE6000-40)
1 to 38 (CE6000-60/120/40Plus/60Plus/120Plus)
3
Offset Angle
Specify the angle to use as the reference to determine if blade angle
control should be performed.
What is Offset Angle (page 19)
Setting range 0 to 60 degrees
4
Data Sorting
Specify whether to store the data in the buffer memory and sort them
before plotting starts.
What is Data Sorting (page 19)
Off
Sorting is deactivated.
On
Sorting is activated.
5
Tool Up Speed
Specify the move speed of the tool when the tool is raised.
Setting range Auto, 10/20/30/40/50/60 cm/sec.
6
Condition Priority
Specify whether the tool conditions can be set or edited with the
command.
Manual
Conditions can be set/edit only from the control panel
or controller.
Program
Conditions can be set/edit with command.
7
Initial Blade
Specify the position at which initial adjustment of the blade direction
is done.
What is initial adjustment of the blade direction (page 19)
2mm Below
(0.08 inch Bellow)
The initial adjustment of the blade direction is done at 2
mm below (0.08 inch Bellow) the start point of the cutting.
Outside
The initial adjustment of the blade direction is done
outside of the cutting area.
8
Tool Up Move
Specify whether the plotter moves the tool each time it receives the
coordinates or directly moves the tool to the last coordinates when
the controller sends instructions in series to the plotter to raise and
move the tool.
Enabled
The tool moves along the coordinates received.
Disabled
The tool moves to the last coordinates.
9
OK
Saves the settings and closes the [Tools Setting] screen.
10
Cancel
Cancels the settings and closes the [Tools Setting] screen.
4
1
2
3
9
10
6
7
8
5