![GRAPHTEC OPS675 User Manual Download Page 18](http://html1.mh-extra.com/html/graphtec/ops675/ops675_user-manual_2257367018.webp)
1 8
In the main screen (
¨
page 9), click
[TOOL] to open the [Tools Setting] screen.
In the [Tools Setting] screen, you make advanced settings for the behavior of the tool and how plotting
data is processed.
4. Tools Setting [TOOL]
8
9
10
11
12
13
1
2
3
4
5
6
7
14
15
1
Step Pass
Set the units by which data is processed. Normally, set the value to [0].
¨
What is Step Pass (page 19)
Setting range
0 ~ 20
2
Offset Force
Specify the cutting force when the direction of the blade is set in the
initial operation. The value is also used as the cutting force when blade
rotation control is performed when tangential emulation is used.
Setting range
1 ~ 40
3
Offset Angle
Specify the angle to use as the reference to determine if blade angle
control should be performed.
¨
What is Offset Angle (page 19)
Setting range
0 to 60 degrees
4
Tool Up Height
Specify the height by which the tool is raised to the surface of the media
(Tool Up). Set how high the tool should be raised from the reference
height.
Setting range
0.0 to 5.0 mm
5
Data Sorting
Specify whether to store the data in the buffer memory and sort them
before plotting starts.
¨
What is Data Sorting (page 19)
Area
Off: Area sorting is not performed.
On: Area sorting is performed.
Tool
Off: Sorting for each tool is not performed.
On: Sorting for each tool is performed.
6
Tool 1-2 Offset
ADJ.*
1
If there is any difference in the drawing, adjust the distance between
Tool 1 and Tool 2. Click [Test Pattern] to cut the test pattern based on the
adjusted setting.
¨
Tool 1-2 Offset ADJ./Tool 1-3 Offset ADJ. (page 19)
Setting range
-3.0 mm to +3.0 mm
7
Tool 1-3 Offset
ADJ.
Adjust the distance between Tool 1 and Tool 3.
Click [Test Pattern] to cut the test pattern based on the adjusted setting.
¨
Tool 1-2 Offset ADJ./Tool 1-3 Offset ADJ. (page 19)
Setting range
-3.0 mm to +3.0 mm
8
Tool Up Speed
Specify the move speed of the tool when the tool is raised.
Setting range
Auto, 10/20/30/40/50/60 cm/sec.
9
Condition Priority
Specify whether the tool conditions can be set or edited from the control
panel of the plotter and from the controller.
Manual
Conditions can be set/edit only from the control
panel.
Program
Conditions can be set/edit from either the control
panel or the controller.