3-81
CHAPTER 3 Settings and Measurement
(2)-13 Backup setting
This device has a function to periodically back up recorded data.
(Refer to the figure below.)
GL980
FTP server
Ethernet
Automatic backup to an FTP server
Measurement input
Auto backup to SD memory card or USB memory
SD CARD
x GB
Lock
(1)
(2)
(3)
Setting
Description
(1) Backup intervals
Set the interval to back up the captured data.
Off, 1, 2, 6, 12, 24 hours ;specified time
(2) Backup Destination
Set the backup destination of the captured data.
Internal memory : The data is backed up to the internal memory of the device.
SD card
: The data is backed up to the SD card.
USB memory
: The data is backed up to the USB memory.
FTP
: Backs up data to an FTP server on the network.
* Capturing destination and backup destination cannot be the same.
* When SD card or USB memory is selected as backup destination, SD card and USB memory
can be replaced. For details, refer to "3.5 Setting Menus" - "7. File menu".
* The FTP server settings must be made using the Interface settings.
(Refer to "FTP/WEB server settings".)
(3) Save folder
Set the folder to save the backup file.
* This must be a folder on the Internal memory,SD card,USB memory or an FTP server.
Example) \GRAPHTEC\¥20171001
If ring capture is On, the backup function is not available.
When set to the CSV file format, the sampling interval is from 10 ms.
To replace the backup destination media, be sure to execute the Remove/Replace in the File menu before
replacing.
If the sampling time is faster because the number of effective CHs is large, or the backup interval is longer,
the size of the data to be backed up increases, so it may take time to finish writing at the time of capturing
stop.
When saving to an FTP server, backup may fail depending on the communication environment and transfer
speed.