Test Modes and Troubleshooting: Error Messages
139
• Set the plotter’s interface conditions to match the software’s interface condi-
tions.
Table 10: Error Messages in HP-GL Command Mode
Symptom
Cause
Solution
An unrecognizable instruction was exe-
cuted.
Execute a recognizable command.
A command was executed with the wrong
number of parameters.
Execute the command with the correct
number or parameters.
A command containing an unusable
parameter was specified.
Execute the command with parameters
specified within their permissible ranges.
An unrecognizable instruction was exe-
cuted.
Specify a recognizable command.
A command was executed with coordi-
nated data that exceeds the effective cut-
ting/plotting area.
Execute the command with its coordinate
data specified within the effective cutting/
plotting area.
The data being input exceeds the capacity
of the plotter’s downloadable character
buffer, polygon buffer, etc.
Increase buffer size.
During the execution of an output com-
mand, another output command was exe-
cuted.
Check the flow of your programmed data.
ERROR 1
NOT RECOGNIZED
ERROR 2 WRONG NUMBER
OF PARAMETERS
ERROR 3 OUT OF RANGE
PARAMETERS
ERROR 5 UNKNOWN
CHARACTER SET
ERROR 6
PARAMETER OVERFLOW
ERROR 7
BUFFER OVERFLOW
ERROR 10 INVALID
I/O OUTPUT REQUEST
Summary of Contents for FC5100-100
Page 3: ......
Page 19: ...Special Precautions Storing the Plotter 18 ...
Page 27: ...Out of the Box Connecting the Plotter 26 ...
Page 33: ...Cutters and Holders Blade Length 32 ...
Page 65: ...Preparing to Cut Returning the Pen Carriage to Origin 64 ...
Page 107: ...Advanced Functions and Settings RS 232C Serial Interface 106 ...
Page 125: ...Background Settings Background Settings for HP GL 124 ...