6-18
Supplement
Press [4] key (CANCEL) to return to the BLADE
WEAR SETUP screen wthout changng any
settngs.
7
Confirm the setting and press the [ENTER] key (SET).
Settng wll be set, and t wll return to BLADE WEAR SETUP screen.
8
Press the [PAUSE/MENU] key.
It wll return to default screen.
BLADE WEAR SETUP (Blade wear factor settings)
Ths settng allows for the adaptaton of dfferent wear rates dependng on the type of meda and the condton
settngs used.
For the plottng pen, modfy dependng on the plottng dstance.
The settng s based on the plottng dstance (1 km) of ol-based ballpont pen.
Pen type
Plotting distance
Coefficient
Ol-based ballpont pen
1000 m
1.0
Water-based fiber-tip pen
500 m
2.0
As shown above, the plotting distance of the water-based fiber-tip pen is half of the oil-based ballpoint pen, so
please use 2.0 as a reference for the coefficient.
Also, n case of the cutter plunger, t may change dependng on the materals and the cuttng force condtons.
The reference value s 4 km.
Blade type
Force
Material
Coefficient
CB09U
8
Coated (glossy) paper 80 g/m
2
1.0
CB15U
8
Coated (glossy) paper 80 g/m
2
1.0
Set the coefficient to a high value when the work load is likely to cause significant wear (this shortens the
maxmum cuttng dstance).
Set the coefficient to a low value when the work load isn't likely to cause significant wear (this lengthens the
maxmum cuttng dstance).
Operation
Supplement
Perform the settngs n Normal menu.
1
Press the [PAUSE/MENU] key.
MENU screen s dsplayed.
2
Press [1] key (TOOL).
TOOL SETTING screen (1/3) s dsplayed.