9.6  

Disposal 

 

The refrigerated bath contains flammable refrigerant gas which must NOT be discharged 
into the atmosphere.  At the end of the equipment

’s working life, either have the gas 

removed safely by using refrigerant recovery equipment or return the equipment to Grant 
Instruments for disposal. 
 

 
9.7 

Service 

 
If service is required, switch off the equipment and contact Grant Instruments or your 
local representative for repairs. 
 
Please note all returned equipment must be accompanied by a Return Materials 
Authorisation (RMA) number, obtainable by contacting the Grant service department 
(details below). 
 
Service Department 
Grant Instruments (Cambridge) Ltd 
Shepreth 
Cambridgeshire 
SG8 6GB UK 
 
Tel: +44 (0) 1763 260 811 
E-mail: [email protected] 

 

 

 

Warning: equipment contains a flammable refrigerant.

 

Summary of Contents for ecocool 100R

Page 1: ...Combined refrigerated and heating bath circulator ecocool 100R Operating Manual EN...

Page 2: ...t Instruments Cambridge Ltd Shepreth Cambridgeshire SG8 6GB UK Tel 44 0 1763 260 811 E mail support grantinstruments com Representative in the European Union Grant Instruments Europe B V Strawinskylaa...

Page 3: ...15 5 1 6 Setting up and switching on 16 5 1 7 Eco mode cooling 16 5 2 Using the equipment 17 5 2 1 Setting the control temperature 17 5 2 2 Selecting liquid type 17 5 2 3 Configuring a pre set 17 5 2...

Page 4: ...ents com 9 5 Routine safety tests 26 9 6 Disposal 27 9 7 Service 27 10 0 Optional accessories 28 10 1 Alternative pump 28 10 2 Pump connectors and other accessories 28 11 0 Troubleshooting 30 12 0 Con...

Page 5: ...se this operating manual This operating manual will allow you to unpack set up and operate this refrigerated and heating bath circulator correctly and safely Important safety information symbols and w...

Page 6: ...the manufacturer the protection provided by the equipment may be impaired This equipment is only for indoor use by a professional user Use only water water glycol or silicone oil with this equipment...

Page 7: ...to ambient temperature and wait until all the ice has melted WARNING Do not damage the refrigerant circuit 4 0 Operating instructions 4 1 Unpacking instructions Standard equipment includes ecocool100R...

Page 8: ...to low liquid level Over temperature cut out has operated Temperature probe fault The cause of the alarm will also be shown on the display The display normally shows the temperature of the liquid bei...

Page 9: ...ain connected at all times Only use the communications port cable supplied with the system Do not connect any other cables or equipment to this communication port Mains Power cable inlet and switch Fo...

Page 10: ...rain insert Place the non connected end of tubing in a receptacle suitable for the liquid to be drained Push the drain insert into the drain port and let the liquid drain To release the drain insert p...

Page 11: ...supplied with the system Do not connect any other cables or equipment to this communication port Mains power outlet for heating circulator 230V equipment only Provides power for 230V heating circulat...

Page 12: ...mains plug and the switch at the rear of the equipment are easily accessible After transport or storage in humid conditions always allow the equipment to stand for at least an hour at room temperatur...

Page 13: ...5 15P plug suitable for North American outlets 230 V equipment Connect the heating circulator using the mains link cable by plugging it into the Mains power inlet on the heating circulator see figure...

Page 14: ...silicone fluids at elevated temperatures Temp range Recommended liquid Comments 20 C to 50 C 50 water 50 antifreeze inhibited ethylene glycol Ethylene glycol is toxic follow the manufacturer s instruc...

Page 15: ...ed at the top right of the heating circulator The over temperature probe independently monitors the bath temperature and switches the heater off if it goes above the cut out threshold Coarse setting o...

Page 16: ...nection Retain the blanking plate for refitting when the pump is no longer required The equipment is supplied with insulated hose which is designed to operate at temperatures between 40 C to 100 C Sui...

Page 17: ...g circulator has started up When working at high temperatures ensure the cables are not touching hot surfaces or air vents Switch on the equipment using the power switch on the front of the refrigerat...

Page 18: ...on s responsibility to assess the risks associated with the choice of heat transfer liquid chosen and to put in place safe working practises and appropriate protective equipment for personnel when con...

Page 19: ...button and rotate the dial until the display shows the correct preset 2 Press the S button to select the preset 3 Press the S button to set the bath to the preset temperature 5 2 5 Setting a countdown...

Page 20: ...the heating circulator will sound the buzzer intermittently and show on the display The alarm can be acknowledged by pressing either the F or S buttons However the alarm is persistent and will trigge...

Page 21: ...f the bath or vessel The calibration of the equipment is performed by setting a low temperature calibration point and a high temperature calibration point The high temperature calibration point must b...

Page 22: ...he temperature on the reference thermometer 7 Press the S button to store the temperature Press the F button to cancel the calibration 5 2 11 Restoring factory calibration settings The restore factory...

Page 23: ...ceed 10 of the nominal supply voltage 6 3 Performance Specification ecocool 100R ecocool 100R AUS ecocool 100R US Typical cooling power at an ambient temperature of 20 C 20 C 250W 0 C 200W 10 C 100W 2...

Page 24: ...e grade of stainless steel It is the excellent forming characteristic that has made this grade dominant in the manufacture of laboratory and industrial water baths as well as domestic sinks and saucep...

Page 25: ...uncontrolled the growth of these organisms can result in a range of serious problems and health risks from pathogenic bacteria The growth of algae on the surfaces will cause bio fouling which can redu...

Page 26: ...ut can be reset correctly If the alarm lamp fails to illuminate when the value indicated on the over temperature dial is more than 10 C below the current temperature as indicated by the main display t...

Page 27: ...replaceable fuse Replacement fuses must be 20mm x 5mm Quick blow type with a F2 5A L 250V rating Fuse replacement should only be carried out by a competent person 9 4 Replacing the mains cord This eq...

Page 28: ...Grant Instruments for disposal 9 7 Service If service is required switch off the equipment and contact Grant Instruments or your local representative for repairs Please note all returned equipment mus...

Page 29: ...pump inlet outlet connector fits 15mm ID T range 50 to 200 C M M16 Stainless steel pump inlet outlet connector M16 x 1 male T range 50 to 200 C M SR4 Metal pump inlet outlet connector dual seal super...

Page 30: ...umentation for the ecocool 100R PQ ecocool 100R PQ documentation for the ecocool 100R A full listing of equipment accessories and options is available in the Grant Scientific Reference Catalogue a cop...

Page 31: ...e is set at least 5 C above the set temperature Refer to section 5 1 2 for setting instructions If the over temperature cut out temperature is correctly set but the equipment still shows a Cut alarm t...

Page 32: ...rature probe Have a competent person check the probe for an open circuit fault or contact Grant Display shows Faulty internal temperature probe Have a competent person check the probe for a short circ...

Page 33: ...tton to return to the home screen Display shows manufacturer factory setting menu There are no user configuration options in this menu Press the F button to return to the home screen For any other err...

Page 34: ...tances hazardous to health RoHS This product complies with the requirements of the UK Restriction of the Use of Certain Substances in Electrical and Electronic equipment Regulations 2012 and the EU Ro...