Integrated Motorized Screen
User Manual for SkyShow
Series Model D
Suitable for Model Named SK-MI(F)
Protecting your Screen:
To ensure long lasting viewing enjoyment keep
the screen rolled up when not in use. Check both
the front and back surfaces before retracting into
the case to make sure it is free of dust, dirt, insects
or other foreign matter. Use a soft brush or cloth to
lightly remove any foreign particles.
Cleaning your Screen:
Use warm water with a mild detergent to remove
any marks on the surface or screen casing (only
dab, do not rub). Immediately dry the screen with
a soft cloth or towel. Do not leave it to air dry.
Never use any solvents, chemicals or abrasive
cleaners on the screen surface as they can
permanently damage the screen surface.
Guangzhou Grandview Crystal Screen CO., Ltd
No. 43 building, South national trade avenue, Hualong town,
Panyu district, Guangzhou City, Guangdong Province, CHINA.
For information please go to www.grandviewscreen.com or
call 86 (020) 84899499
Screen: Voltage AC220-230V/50-60HZ, 0.27Amp, power 60watts.
RF remote(F): Voltage 3V, use CR2450*1 battery.
Radio Frequency: 433Hz. maximum control distance 15m.
Setting for Up and Down Limited Positioning for Motor:
The limited positioning of motor has been defaulted when
EX-factory, it is not allowed to reset.
Note:
When setting RS232 or RS485, if the screen is not able to
operate as it is, please switch position of No. 1 and No. 2.
The electric resistance of return circuit is less than 20
Ω
.
Do not do wiring nearby interference sources.
S1 SW-PB
S2 SW-PB
S3 SW-PB
STOP
UP
DOWN
8P8C
RS
-
232
P1
8
7
6
5
4
3
2
1
1
6
2
7
3
8
4
9
5
1
RS485-B
RS232-GND
2
3
4
5
6
7
8
RS485-A
RS232-TXD
8 7 6 5 4 3 2 1
R 45
J
Dry Contact,RS485 & RS232 Wiring Map:
Line
Function
STOP
UP
DOWN
COMMON
LINE
COMMON
LINE
RS485/RS232 control protocal:
Baud Rate: 2400
Data Bits: 8
Stop Bits: 1
Parity: None
Hex command:
Screen UP: ff ee ee ee dd
Stop: ff ee ee ee cc
Down: ff ee ee ee ee
In some cases you may need to
enable the RS-232 control by
sending hex command:
ff ee ee ee aa
USB Serial Port (COM3) Property
Detail Event
Drive Program
General Port
Confirm
Advanced
Restore
Baud Rate: 2400
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
Cancel