![Grandview Sky-Show User Manual Download Page 1](http://html1.mh-extra.com/html/grandview/sky-show/sky-show_user-manual_2256466001.webp)
Grandview Sky-Show
User Manual
Imported and Distributed in Australia by
Herma Technologies
Factory 4A, 6 Albert St
Preston, VIC 3072
For more information please go to
www.grandviewscreens.com.au
or call 1300 730 025
Protecting Your Screen:
• Keep away from direct sunlight or
high temperatures.
• Examine both the front and back
surfaces before retracting into the
case to make sure it is free of dust,
dirt, insects or other foreign matter.
• Use a soft brush or cloth to lightly
remove any foreign particles.
Cleaning Your Screen:
• Do not use any solvents, chemicals
or abrasive cleaners on the
screen surface.
• Use a mild detergent with warm water
to remove any marks on the surface or
screen case.
• Always immediately dab the screen
with a soft cloth to avoid soap marks.
• Do not scrub the surface.
Warranty: 12 Months
RS 232/485 Input Settings / Close Contact
Back View
1
2
3
4
5
6
7
8
Crystal Socket
Control Emitter Function / Address
1
Common line
5
Casing Down
2
Retracting the screen
6
Stop
3
Lowering the screen
7
Rs232 Input B
4
Casing up
8
Rs232 Input A
EXTERNAL CTRL
1
2
3
4
5
6
7
8
J1
8P8C
RS-232
P1
5
2
1
6
7
8
9
4
3
UP
S5
Stop
SW-PB
S1
S4
S3
S2
SW-PB
SW-PB
SW-PB
SW-PB
Casing Down
Casing Up
ScreenDown
Screen Up
1. Central Control Format Agreement Communication
Agreement Setting:data bits: 8 bits, start bits: 1 bit,
stop bits: 1 bit, Baud Ratio: 2400.
2. Retracting the screen:
oxFF oxEE oxEE oxEE oxDD
3. Stopping the screen:
oxFF oxEE oxEE oxEE oxCC
4. Lowering the screen:
oxFF oxEE oxEE oxEE oxEE
5. Retracting the casing:
oxFF oxEE oxEE oxEE oxC9
6. Lowering the casing:
oxFF oxEE oxEE oxEE oxE9
7. 232 setting: 2400, n, 8,1 a continuous data sends
two times, each time interval of 200 ms.
Cable
Box
Ethernet Cable Box
Retractor
Central Control Input
GV_Sky_Show_Jun11_v1.2