37
16.
DIGITAL OUTPUTS CONFIGURATION
This section allows the configuration of the optional 3-relay board available
for the
K3X
terminal.
These 3 relay outputs can be used either for controlling an external signalling
of the high/low/ok limits in the operation mode as a checkweigher (H-L
mode) or for dosing a product. Moreover, it is possible to select whether the
dosing is performed for filling a receptacle on the scale (loading) or for
emptying a receptacle (unloading). The options in this section of the menu
are the following:
Operation mode for controlling the optional relay board.
The relay outputs will be controlled by the H-L
operation mode. The K1 relay closes when the weight
on the scale is greater than the limit
. The K2
relay closes when the weight is between the
and
limits. The K3 relay closes when the weight is
below the
value.
The relay outputs will be controlled by the dosing
mode.
Allows each one of the 3 relays to be test and operated by
the user.
Setting the upper and lower values for running the
“checkweigher” mode.
Value of the lower limit, including the decimal part.
Value for the upper limit, including the decimal part.
Yes / No: Activating the limits control when switching
on the unit. The H-L key activates or deactivates the
limits control.