Gram Baker SF 1500 G Operating And Service Manual Download Page 1

765042364 

 

Rev.000 

 
 
 
 
 
 
 
 

 
 

Operating- and Service manual 

Baker SF 1500 G 

 
 

When  installing  this  appliance,  it  is  of  great  importance  to 
make sure that the size of the room, where the cabinet is to 
be  installed,  is  being  taken  into  consideration,  in  order  to 
comply  with  safety  regulations.    For  further  explanation 
look under “Location”. 

Summary of Contents for Baker SF 1500 G

Page 1: ...500 G When installing this appliance it is of great importance to make sure that the size of the room where the cabinet is to be installed is being taken into consideration in order to comply with saf...

Page 2: ...AFETY INFORMATION 18 LOCATION 19 DEFROST WATER 21 GENERAL DESCRIPTION 22 REFRIGERANT GWP VALUE 23 CLIMATE TEMPERATURE CLASS 23 ELECTRICAL CONNECTION 24 DIRECTIONS FOR DAILY USE 25 STARTING UP 27 TIME...

Page 3: ...en and also for the workers in the factory here in Vojens All different settings are categorize and placed in submenus The access comes through main menus MPC 46 and the menus The menus are divided up...

Page 4: ...he display during normal operation 0 The door is open The alarm system is activated if the door is not closed within a certain time The user is reminded that the door is not properly closed F1 Cabinet...

Page 5: ...s to indicate that a defrosting cycle is running The next defrosting runs automatically 6 hours later Defrosting can be set from 1 to 8 times per 24 hours See chapter User menu Manual defrosting If th...

Page 6: ...dicator flashes Push the P button to start the cycle The thawing LED indicator is turned on After conclusion of the thawing cycle the current storage process continues Dry refrigeration programme Dry...

Page 7: ...e keypad is not activated for 15 seconds the controller returns to normal operation Temperature controlled chilling hard chill This program runs by the temperature of a sensor placed at a warmer spot...

Page 8: ...isplayed as shown in the diagram above 8 8 C To set the temperature use the plus minus keys Press the P button to save the setting and the process starts immediately The indicator is turned on To canc...

Page 9: ...r The buzzer sounds at alarms A1 A2 A3 1 on 0 off External alarm setting EAL EhL C Setting the upper alarm limit At alarm the display shows A4 ELL C Setting the lower alarm limit At alarm the display...

Page 10: ...nu access P Alarm setup A A1 C In case of condenser overheat compressor protection cycle is started A2 C Condenser temperature which disconnects the compressor protection cycle A3 min Re enter time fo...

Page 11: ...ed C6 min Compressor stop by open door C7 K Soft differential for cool heat cut out kelvin C8 C Setpoint for condenser fan C9 K Cut out differential for condenser fan kelvin Evaporator fan F F1 C Temp...

Page 12: ...the display glows with on The desired relay conducts now power to the electrical component Push the button to switch off the power from the electrical component Leave the service program with the butt...

Page 13: ...ser sensor 2 P d Condenser sensor 1 measurement is displayed F4 Condenser sensor 2 error Extra sensor P E Extra sensor measurement is displayed F5 Extra sensor error An overheated condenser could be c...

Page 14: ...arm settings A Condenser monitoring alarm on celcius A1 65 65 65 65 65 65 65 65 65 65 65 65 Condenser monitoring alarm off celcius A2 40 40 40 40 40 40 40 40 40 40 40 40 Genindtr delses tiden for akus...

Page 15: ...Volt relay K7 and K8 The relay supplies the front frame heater re evaporating heating element and the condensing pump with power When the cabinet is switched on the power is constantly viable 11 12 13...

Page 16: ...2364 Rev 000 16 A Room sensor input NTC sensor B Evaporator sensor input NTC sensor C Condenser sensor input 1 NTC sensor D Condenser sensor input 2 NTC sensor E Sensor input for a extra sensor NTC se...

Page 17: ...ns with proper knowledge of the product and only using original spare parts Changes in installation and other use of the product than prescribed in this manual might affect the operation and durabilit...

Page 18: ...ith sharp edges in the compressor compartment and in the inside compartment The product is not to be transported on a sack truck there is a danger of loosing the balance causing danger to persons Prio...

Page 19: ...d examine the cabinet for any damage The set up place must be level and horizontal To remove the transport pallet the cabinet must be layed down on its back The heaviest part of the cabinet is at the...

Page 20: ...lation around the cabinet In order to do so the following demands must be met Minimum free height above the cabinet 500 mm Minimum free space behind the cabinet 50 mm distance created by the two dista...

Page 21: ...defrost water is led through a pipe on the backside of the product The defrost water must be led to an external drain To prevent backflow do not connect the drain hose tube directly to the sewer syst...

Page 22: ...765042364 Rev 000 22 General description Compressor Condenser w filter Receiver Vent inlet w filter Control panel Controller Door Air inlet Air outlet Gasket Buffer rails Floor w ramp...

Page 23: ...500 G R290 0 235 0 225 3 1 38 Climate temperature class Products in this category are tested according to the following climate classes Information about the climate class applicable for the different...

Page 24: ...e product Only the supplied detachable cord is to be used Never use an extension cord for this product If a wall socket is placed in a longer distance than the length of the supplied power cord contac...

Page 25: ...still be voltage to some electrical parts of the product Directions for daily use Do not block vent holes in the front panel Do not damage the refrigeration system parts During normal operation some p...

Page 26: ...e If the product is turned off wait minimum 3 minutes before turning it on again This is to protect the compressor from damage Do not store explosive substances such as aerosol cans with flammable pro...

Page 27: ...isregarded The refrigeration system runs constantly and the process stops when the set time has elapsed The process is started in this way Push the button The display shows HCL for 1 second Then the s...

Page 28: ...hes To set the temperature use the plus minus keys Press the P button to save the setting and the process starts immediately The indicator is turned on To cancel push the ON OFF button and the cabinet...

Page 29: ...ge of the setting procedure If the keypad is not activated for 15 seconds the controller returns to normal operation Be aware that the lower setpoint temperature may vary according to the substance an...

Page 30: ...on to start the defrost cycle The defrost LED indicator is turned on After conclusion of the defrost cycle the current chilling or storage process continues Do not use sharp or pointed objects to acce...

Page 31: ...e temperature sensor on the evaporator This has no effect on the operation of the cabinet but the sensor should be replaced as soon as possible Request service assistance F3 If the display alternates...

Page 32: ...n Damaged door gasket Cabinet temperature setting too high Cabinet too packed with foods air inlet outlet blocked Condenser mesh filter is clogged Warm or hot foods inside Defrost in progress The cabi...

Page 33: ...water jet or steam hose as this may cause short circuits in the electrical system Cleansing agents containing chlorine or compounds of chlorine as well as other corrosive means are not to be used as...

Page 34: ...tched off at the socket or whether a fuse has blown If it is not possible to find the cause of the refrigeration failure please contact your dealer When ordering service for the appliance it is of gre...

Page 35: ...sed out wheelie bin is considered electric and electronic equipment The crossed out wheelie bin symbolizes that waste of this type cannot be disposed of with unsorted municipal waste but must be colle...

Page 36: ...the extent necessary to comply with the relevant directives DS EN 12100 2011 Safety of machinery General principles for design Risk assessment and risk reduction DS EN 60335 1 2012 Household and simil...

Page 37: ...n Sheetsize Drawing no X XX Description Revision Generel tolerance ISO 2768 m ISO 286 2 Sheet no Rev All rights to this drawing belongs to Gram Commercial A S cf law of Copyright Thus the drawing shou...

Page 38: ...38 765042364 Rev 000 Piping diagram...