750000-INS-LAB-RevA08

danger

to reduce the risk of electrocution:

DANGER: Always unplug this product immediately 

after using.
DANGER: Do not use this product while bathing.
DANGER: Do not place or store this product where it 

can fall or be pulled into a tub or sink.
DANGER: Do not place this product in or drop into 

water or other liquid.
DANGER: Do not reach for a product that has fallen 

into water. Unplug it 

immediately

.

WarnIng

To reduce the risk of burns, electrocution, fire, or 

personal injury:

WARNING: Do not leave this product unattended 

when plugged in.
WARNING: Always use close supervision when this 

product is used by, on, or near children or those who 

require close supervision.
WARNING: Use this product only as intended and 

described in this manual. Do not use attachments or 

accessories not recommended by Graham-Field.
WARNING: Never operate this product if 

a) it has a damaged cord or plug

b) it is not working properly

c) it has been dropped or damaged

d) it has been dropped into water.

Return the product to your Graham-Field equipment 

provider.

Summary of Contents for LUMEX AltaDyne 750000

Page 1: ...ernating Pressure Low Air Loss Mattress System User Manual Important Do not operate the Mattress System without first reading and understanding this manual Save this manual for future use 750000 INS L...

Page 2: ...TRESS INSTALLATION 9 Operation 11 Pressure adjustment 11 Quick disconnect 12 Transport cap 12 CPR function 12 Maintenance 12 Cleaning 12 GENERAL Maintenance 13 Fuse replacement 13 Air filter replaceme...

Page 3: ...r refer to the basic safety information that should be observed by those using the Alternating Pressure Low Air Loss Mat tress System There are additional safety statements in other chapters or sectio...

Page 4: ...ng To reduce the risk of burns electrocution fire or personal injury WARNING Do not leave this product unattended when plugged in WARNING Always use close supervision when this product is used by on o...

Page 5: ...ilar particles WARNING Never drop or insert any object into any opening or hose WARNING Do not use this product in the presence of flammable anesthesia or where oxygen or nitrous oxide is being admini...

Page 6: ...lectrical Electronic Equipment WEEE Do not treat this product as household waste For more detailed information with regard to returning and recycling this product please consult your local city office...

Page 7: ...750000 INS LAB RevA08 Product description Pump and mattress system pump and mattress system CPR valves mattress pump connectors mattress foot end symbol pump Pump front quick connector...

Page 8: ...nter clockwise to de crease air output pressure softer Higher pressure output will better support the heavier weight user The setting is measured in kilograms kg Please consult your physician for an a...

Page 9: ...1 Before unpacking check for obvious damage to the car ton or its contents If damage is evident please notify the carrier and your Graham Field equipment provider 2 Remove all loose packing from the...

Page 10: ...under the mattress WARNING Locate all cords so that they will not be stepped on tripped over or otherwise subjected to damage or stress WARNING Do not use a household extension cord if the electrical...

Page 11: ...e indica tor will de illuminate and the normal pressure indicator green LED will automatically illuminate 5 Replace all sheets blankets and pillows on the bed Pressure adjustment Generally a lighter p...

Page 12: ...ly Transport cap In case of power failure or transport Disconnect the quick connector and cap the mattress with the transport cap to slow deflation CPR function If CPR must be performed on the patient...

Page 13: ...k main power cord and plug for abrasion or exces sive wear 2 Check mattress cover for signs of wear or damage En sure mattress cover and tubes are connected correctly 3 Check airflow from the air hose...

Page 14: ...is dirty Storage 1 Lay the mattress out flat and upside down 2 Roll from the head end toward the foot end 3 Stretch the foot end strap around the rolled mattress to prevent unrolling 4 Store mattress...

Page 15: ...use in the presence of a flammable anesthetic mixture No AP or APG protection Mattress Specification Model 8 mattress Dimensions L x W x H 78 7 x 35 4 x 8 200 x 90 x 20 3 cm Weight 22 1 lb 10 0 kg Arr...

Page 16: ...quarters Graham Field Health Products 2935 Northeast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232 www grahamfield com 750000 INS LAB RevA08 2008 GF H...