SILENTIO“ system control

Fill level measuring device and drinking

water supply

Item no.: 351022

Otto Graf GmbH

Carl-Zeiss-Str. 2-6

Tel .: 07641-5890

Kunststofferzeugnisse

D-79 331 Teningen

Fax: 07641-58950

Page 1

Summary of Contents for SILENTIO

Page 1: ...mation SILENTIO system control Fill level measuring device and drinking water supply Item no 351022 Otto Graf GmbH Carl Zeiss Str 2 6 Tel 07641 5890 Kunststofferzeugnisse D 79 331 Teningen Fax 07641 58950 Page 1 ...

Page 2: ...d malfunction 5 Operating buttons 6 Serial number 7 Lower cover of the System Control 8 Main connection cable with power coupling for data lead 9 Pre stamped breakthrough for upgrading features 10 Mains power coupling for data lead supply cable 11 The mains circuit breaker of the system controls are under this cover Page 2 ...

Page 3: ...Figure 2 Sensor assembly 12 Data cable 13 screw cap 3 14 Connection of the data cable is reverse protected 15 connect white cable here 16 connect red cable here Page 3 ...

Page 4: ...ser Guide Manual to achieve the optimal performance Please keep these safety and operating instructions safe for further use General Safety Instructions Symbol Explanation refers to an information means warning and indicates a special situation indicates a hazardous situation which may cause to heavy or serious injury or even death 1 1 Personnel The installation commissioning and dismantling of th...

Page 5: ... life from electric current Direct contact to the parts of the device will cause an electric shock In case of damage to the insulation the device must be switched off immediately and the damaged area must be de energized While maintaining on the device ensure that the power supply is off at all times and make sure the device is de energized 1 5 Electric Shock If objects e g hairpins needles or coi...

Page 6: ...ng objects on the device such as newspapers books or towels 1 10 Water and Moisture The device is not allowed to operate in close vicinity of electrical conductive liquids or moist areas It is not allowed to place any liquid things on the device or in the nearby area of the device Attention Danger of Electric Shocks 1 11 Temperature and Heat The operating temperature of the device is defined in th...

Page 7: ... safety values are mentioned in the manual The guarantee for this equipment will expire in case of using other fuses than those specified in the manual 1 16 Repairing The user is not allowed to perform the maintenance work by himself except for those specified in the manual All maintenance and repair work must be done by trained and authorized technical personnel 1 17 Important notes on safety Spe...

Page 8: ...tems It can be used with a wide variety of tank systems Tanks made from metal or steel reinforced cement may only be used when the following conditions have been correctly followed Metal tanks lead to faulty readings Helpful is to assemble the device so that the sensor is as far as possible from the metal sides so for example in the centre of a cylindrical tank The system controls offer an easy to...

Page 9: ...ly by the mains supply via the mains fuse The yellow LED indicating Drinking water operation is lit as soon as the valve switches over to the mains supply The user is made aware that the system now uses water from the mains supply The red LED for Faults and malfunctions is lit as soon as the system identifies a fault The display will then show a warning that describes the cause of the fault in pla...

Page 10: ...ent pick up 28 3 Shorten the connection cable to suit the measured height 4 Connect the sensor cable to the sensor as described in the following instructions Remove between 5 7 mm of the insulation from both of the cables Next pass the red cable through the screw mounting 1 19 and tighten this lightly then connect the red cable to the terminal 16 The free white cable is now passed through the scre...

Page 11: ...rainwater filter please read on from point 3 Putting into op eration Before connecting the Rainwater usage system please ensure there is no over straining or tension on any of the connections The plug of the system control unit must not be connected to the socket of the electrical supply Pass the end of the cable from the solenoid valve for the rainwater cleaning filter through the threaded gromme...

Page 12: ...tral conductor P 230V AC PE Ground Earth Figure 4 Electrical diagram for filter flushing valve After connecting the wires close the lower cover 7 of the system control housing 4 4 Electrical connection of the additional pump Connection of the additional pump is optional If running the system without the additional pump please read from point 3 putting into operation Before opening the equipment pu...

Page 13: ...ble in the proper manner Pass the cable through the grommet opening in the system control unit housing Connect the protective earthing conductor green yellow wire core on a free terminal with the designation PE Ground Connect the neutral wire core blue on a free terminal with the designation 5 Connect the live electrical supply wire core brown or black on a free terminal with the designation 2 pow...

Page 14: ...the first line the system type will be shown and in the second line the software position will be shown After the correct initialisation of the system installation has been acknowledged the LCD display will show the fill level as a percent The first running of the unit will show the fill level reference point that is according to the standard factory setting tank height Standard factory setting va...

Page 15: ... by the LCD For the set up follow all the points listed in table 1 in the sequence as shown Should any error in the sequence occur then it is necessary to begin the set up again from the beginning starting with the tank height Begin the programming of the settings by pressing the button marked MENU With the buttons or the menu may be scrolled backwards and forwards With the respective menu point s...

Page 16: ...released The menu structure integrated in the system control is introduced to familiarise the user in diagram 9 To bring up the menu press and hold the MENU button for longer than 5 seconds All outlets are inactive when the menu level has been activ ated The operation of the device is suspended The system control switches auto matically back to the operating mode when no entries have been received...

Page 17: ...es for 30 seconds DW DURATION 0 60 SEC 30 Cleaning the rainwater filter every 14 days The value 0 switches the cleaning process off CLEANER INTERVAL 0 14 DAYS 14 Cleaning the rainwater filter for 5 seconds CLEANER DURATION 0 60 SEC 5 CLEANER RINSE AT INCREMENT 2 Cleaning the rainwater filter when the fill level has increased by 2 after rainfall If the fill level continues to increase the rinsing w...

Page 18: ... Sub menu General device description The last part of the operation level covers the manual functions Page 18 DEVICE ADJUSTMENT LANGUAGE ENGLISH key ENTER 20 in Figure 2 A 6m Sensor may be ordered MEASURING LENGHT 30 600cm 200 MANUAL OPERATION LAST FLUSH DW 0 key ENTER HAND FLUSH DW NO Time scale in days the time elapsed since the last flush using mains drinking water Activation of the flushing pr...

Page 19: ...s Please also take note that the system control device cannot identify any malfunction of the house water system No malfunction signal is supplied by the house water system to the system control device If faults are recognized by the sensors the system control cannot continue to work independently The particular faults are shown on the plain text in the display Page 19 LAST RINSE CLEANER 1 HAND RI...

Page 20: ... SYSTEM For further diagnosis remove the stainless steel weight 22 out of the water If the error indication has now stopped then the sensor it self was the cause of the fault If the error indication should continue this implies that the measurement pick up is defect ERROR NO SIGNAL The communication between the system control to the measurement pick up is interrupted ERROR MEMORY First try re sett...

Page 21: ...9 3984 80 69 61 Internet http www aktuatorikundsensorik com E Mail info AS Prenzlau de We prefer to receive an E Mail if you must contact us then be sure to enter the serial number of your controller that begins with AS The serial number is found on the name type label 8 Upgrade options The SILENTIO control device can also be equipped with a number of additional special functions 1 Optional pressu...

Page 22: ...tional switch output point 9 General installation and assembly regulations It is necessary to these instructions when installing a rain water usage equipment EN 806 Drinking water installation Planning and implementation Calculation of the pipe diameters Using the equipment EN 1717 free outlet between drinking and rainwater Notification sign to inform that a rainwater usage system is installed in ...

Page 23: ...from the system control 0 100 by a voltage range from 0V to 10V The following connection values apply Minimal apparent ohmic resistance 20K Ohm Short circuit protection Yes Short circuit current Approx 15mA Cable length maximum 200m shielded Note The system control is only capable of displaying whole percent values no fractions These are shown on the analogue signal display A maximum of one digit ...

Page 24: ...t occurs as soon as one of the malfunctions listed under Point 6 appears The picture on the following page shows the location of the connections These become available as soon as the lower cover of the system control unit is opened see 7 in diagram 1 Before opening this cover it is important to disconnect the device from the mains electricity supply Before opening the equipment pull the plug out f...

Page 25: ... fault indicator The M 12 M16 opening on the underside of the system control device must be opened and the cable drawn through Place the supplied grommet into the opening and pass the cable through into the system control Page 25 ...

Page 26: ...ut the mains plug from the socket before opening the device Warning of dangerous electrical voltage Attention An error has occurred Mains drinking water operation Page down Page up Protection classification I Only for use in a dry areas Page 26 ...

Page 27: ...Room for your notes Page 27 ...

Page 28: ...02 18 Formatting SU Room for your notes Purchase date Device serial number Type AS SI Active measuring length Software level SILENTIO REV Design and specifications are subject to change without notice Dated February 2018 Version SI 3 4 man_Silentio_3 4_eng odt Page 28 ...