Setup
30
3A6283F
Connect Static Mixers, Gun, and
Hoses
1. Connect the outlet of the two primary static mixer
tubes (AW) to the gun and hose assembly (ZU).
2. Check that all connections are tight.
Add Heating Fluid to Heated
Hoppers
1. Use a 50/50 mixture of water and ethylene glycol
(engine coolant) for heating fluid in the outer cavity
of the hopper. Approximately 12 gallons (45 liters) of
heating fluid is needed for each hopper.
NOTE:
The ethylene glycol mixture provides the fastest
heat-up time and prevention of algae build-up
regardless of ambient temperature. Oil can be used but
heat-up time will increase and the hopper level needs to
be lower to allow for thermal expansion.
2. Remove fill port cap (ET) and pour heating fluid in
the outer cavity through the fill port (EK).
NOTICE
To prevent creating a flare on the mixer tube, do not
use a union swivel end on the mix tube inlet.
:
=8
$:
WLE
$:
$:
NOTICE
Other glycols (RV/Marine Antifreeze) are not
recommended for use as a heating fluid. These
materials are not rated for higher temperatures and
could cause damage to the immersion heaters.
ti33983a
Temperature
Time
Spray material temperature
Oil
ethylene glycol mixture
(.
(7
Summary of Contents for XP50s-hf
Page 61: ...Parts 3A6283F 61 XP50s hf and XP70s hf Proportioners Continued WL F ...
Page 64: ...Parts 64 3A6283F Water Jacketed Heated Hose Packages WL D 2 2 2 247 246 245 ...
Page 66: ...Parts 66 3A6283F Non Heated Hose Packages WL D 2 2 ...
Page 68: ...Parts 68 3A6283F Non Hazardous Location Electric Heated Hose Packages WL D 480V 240V ...
Page 69: ...Parts 3A6283F 69 Hazardous Location Electric Heated Hose Packages WL D 9 9 ...
Page 82: ...Dimensions 82 3A6283F Dimensions System Dimensions WL D LQ FP LQ FP LQ FP Top View Side View ...