Appendix B - ADM Setup Screens Overview
64
313875J
Advanced #3
This screen allows the user to control the availability of
some key system features.
•
Disable Dispensing From Display:
Check this box
to disable dispensing from the ADM. A footswitch,
dispense valve trigger, or other external signal will
be the only way to initiate a dispense.
•
Disable Modifying Temp Setpoint:
Check this box
to disable modifying temperature setpoints from the
Run screens. This is only applicable if temperature
control items are installed and enabled.
•
Disable Operator Mode Flow Adjustments:
When
checked, the user will not be able to change the flow
on operator mode Home Run screen.
•
Disable Operator Mode Ratio Adjustments:
When checked, the user will not be able to change
the ratio on operator mode Home Run screen.
•
Temperature Alarm Disables Dispense:
When
checked, any active alarm from any temperature
zone will disable dispensing.
•
Complete Dispense with Setpoint Error:
When
this box is checked, the shot will continue dispens-
ing even if the system never reaches the desired
setpoint.
•
Enable Shot Aborted Notification:
When this box
is checked, a pop-up notification will be displayed
when a shot is aborted.
•
Enable Ratio Check Weight Mode Entry:
This
option is for machines without flow meters. When
this box is checked, after any ratio check shot a
popup window will appear asking the user to enter
the dispensed weights. Press the Cancel button to
abort the entry or press the Enter button to record
the new values.
Advanced #4
This screen is for enabling the optional Diagnostic
screen and for enabling USB log downloading and USB
errors. For more information about USB operation, see
information about the optional screens, see
screen on page 68.
Advanced #5
This screen displays software information.
Numbers shown are for reference only and may
be different on your system.
Summary of Contents for VPM 12
Page 9: ...A Red and B Blue Components 313875J 9...
Page 50: ...Maintenance 50 313875J...