background image

Ultra

®

 Max II 

ProContractor

Mark Max 

ProContractor

www.graco.com

OPTIONS

Quick Operator’s Guide

SETUP

This procedure is for water-base paints and flushing fluids. For solvent-base paints and flushing

fluids (i.e. mineral spirits), you must read Fire and Explosion Hazard in the Operating Instructions.

* check the Graco operations manual delivered with the unit for more details.

WARNING

Place siphon tube in pail

partially filled with water.

Aim gun at inside

wall of water pail

and squeeze 

trigger.

Keeping gun triggered 

into water pail, turn prime 

valve to Spray position 

(horizontal).

Fill throat packing nut with TSL™

to prevent premature packing wear.

Remove guard and SwitchTip

Turn pressure control knob
to lowest pressure, and set

power switch to ON.

Increase pressure until

sprayer starts. Keep 

gun triggered into 

water pail.

Turn prime valve
to Prime position 

(down).

Make sure power

switch is set to OFF.

Increase pressure until

sprayer starts and water

runs out of prime tube.

Let water run out of prime

tube for 15 seconds.

When water comes out of gun, 

turn pressure to lowest setting. 
Trigger gun to relieve pressure.

When paint comes out of 

gun,release trigger and turn 

safety lever of gun to ON.

Empty displays/flashes and pump stops when WatchDog

protection system detects an empty material pail.

Decrease pressure

until sprayer stops.

Place siphon tube in 

paint pail, but leave 

drain tube in water pail.

Transfer drain

tube to paint pail.

Turn prime valve

to Prime position (down).

Make sure safety

lever of gun is OFF.

Increase pressure until

sprayer starts and paint

comes out of drain tube.

Turn WatchDog switch ON

and WatchDog ON displays.

Plug electrical cord

into grounded outlet.

Turn prime valve
to Spray position

(horizontal).

Screw tip & guard onto gun, making sure arrow-shaped 

handle of tip is pointing forward. You can reverse this tip to 

quickly clear clogs without taking it apart.

Turn WatchDog switch OFF. 

Add material or reprime sprayer.

Turn pump switch OFF and ON 

to reset WatchDog protection system.